U905
Option Cnt
Description
Displays the counts of DP.
Purpose
To check the use of DP.
Method
1. Press the start key.
2. Select [DP]. The count is displayed.
Display
DP
Method: [DP]
Display
ADP
RADP
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U906
Reset Dis Func
Description
Resets the service call code for partial operation control.
Purpose
To be reset after partial operation is performed due to problems in the casettes or other sections,
and the related parts are serviced.
Method
1. Press the start key.
2. Press [Execute].
Display
Execute
3. Press the start key to reset partial operation control.
4. Turn the main power switch off and on. Allow more than 5 seconds between Off and On.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Counts of DP
Counts of single-sided originals that has passed through the DP.
Counts of double-sided originals that has passed through the DP.
Resets the service call code for partial operation control.
1-3-114
2NC/2NF/2NG/2NN/3P7/3P8/3P9
Description
Description
Description