U100

Main HV Output

Description
Performs main charging.
* : Perform the high altitude settings when a leakage is developed on images in a high altitude
installation, such as in Mexico City.
Purpose
To check main charging.
Method
1. Press the start key.
2. Select the item to be set.
Charged Voltage
High Altitude
Setting: [Charged Voltage]
1. Select the item to be set.
2. Change the value using change keys * or numeric keys.
* : Zoom/Paper selection key (Basic model), Right/Left arrow key (Advanced model)
Display
Execute
Voltage
3. Press the start key. The value is set.
Setting: [High Altitude]
1. Select the mode to be set.
Display
Mode0
Mode1
Mode2
* : Initial setting: 0
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for maintenance item No. is displayed.
Display
Description
Aging is performed.
The amount of adjustments of charged
voltage.
Set mode0 of high altitude mode. (1500 m or less)
Set mode1 of high altitude mode. (1500 m to 2500 m)
Set mode2 of high altitude mode. (2500 m or more)
1-3-44
2NC/2NF/2NG/2NN/3P7/3P8/3P9-2
Setting
range
-
-100 to 100
Description
Initial
setting
-
0