5. Change the setting value using change keys * or numeric keys.
* : Zoom/Paper selection key (Basic model), Right/Left arrow key (Advanced model)
For output example 1, increase the value. For output example 2, decrease the value.
Center line of printing
(within ± 2.0 mm)
6. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following
adjustments in maintenance mode.
U034 -------- U067 -------- U072
(P.1-3-34)
A feed setup is performed as follws.
Select item
LSU Out Top :MTP
LSU Out Top :Cas1
LSU Out Top :Cas2
LSU Out Top :Cas3
LSU Out Top :Cas4
LSU Out Top :Duplex
LSU Out Left :MTP
LSU Out Left :Cas1
LSU Out Left :Cas2
LSU Out Left :Cas3
LSU Out Left :Cas4
LSU Out Left :Duplex
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Correct image
(P.1-3-39)
Feed
MP Tray
Cassette1
Cassette2
Cassette3
Cassette4
Cassette1
MP Tray
Cassette1
Cassette2
Cassette3
Cassette4
Cassette1