4. Remove the retard holder and the
retard roller by bending to inside the ful-
crum part of the retard holder.
*: Be careful not to skip a spring.
5. Check or replace the retard roller and
refit all the removed parts.
6. When replacing the new unit,proceed
as follows:
1)Performs maintenance mode U901
(Clr Paper FD Cnt) (see page 1-3-111).
Fulcrum section
Retard holder
Projection portion
Spring
1-5-9