Kyocera TASKalfa 3510i Service Manual page 135

Hide thumbs Also See for TASKalfa 3510i:
Table of Contents

Advertisement

Item No.
5. Change the setting value using the +/- keys or numeric keys.
U034
For output example 1, increase the value. For output example 2, decrease the value.
Leading edge
registration
(20 ± 1.5 mm)
6. Press the start key. The value is set.
Remark
Changing the larger sizes settings affects those for the smaller sizes.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following
adjustments in maintenance mode.
U034
Adjustment: LSU Out Left
1. Press the system menu key.
2. Press the start key to output a test pattern.
3. Press the system menu key.
4. Select the item to be adjusted.
Display
MPT
Cassette1
Cassette2
Cassette3
Cassette4
Duplex
Description
Correct image
Figure 1-3-4
U066
U071
( P.1-3-43)
( P.1-3-48)
Description
Paper feed from MP tray
Paper feed from cassette 1
Paper feed from cassette 2
Paper feed from optional
cassette 3
Paper feed from optional
cassette 4
Duplex mode (second)
1-3-35
Output
Output
example 1
example 2
Setting
range
-128 to 127 0
-128 to 127 0
-128 to 127 0
-128 to 127 0
-128 to 127 0
-128 to 127 0
2NL/2P8
Initial
Change in
setting
value per step
0.1 mm
0.1 mm
0.1 mm
0.1 mm
0.1 mm
0.1 mm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 3010i

Table of Contents