U327 Setting The Cassette Heater Control; U332 Setting The Size Conversion Factor - Kyocera TASKalfa 3510i Service Manual

Hide thumbs Also See for TASKalfa 3510i:
Table of Contents

Advertisement

Item No.
U327
Setting the cassette heater control
Description
Sets the cassette heater control.
Purpose
To change the setting according to the machine installation environment.
Setting
1. Press the start key.
2. Select [On] or [Off].
On
Off
Initial setting: Off
3. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U332
Setting the size conversion factor
Description
Sets the coefficient of nonstandard sizes in relation to the A4/Letter size. The coefficient set here
is used to convert the black ratio in relation to the A4/Letter size and to display the result in user
simulation.
Purpose
To set the coefficient for converting the black ratio for nonstandard sizes in relation to the A4/Let-
ter size.
Setting
1. Press the start key.
2. Change the setting using the +/-keys or numeric keys.
Display
Rate
3. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Display
Cassette heater ON
Cassette heater OFF
Size coefficient
Description
Description
Description
1-3-109
2NL/2P8
Setting
Initial
range
setting
0.1 to 3.0
1.0