Pn508
Undervoltage Alarm Selection
Setting
0 to 1
range
Select either to let the servo off or to stop the alarm when a main power alarm occurs.
Explanation of Set Values
Set value
Servo is turned OFF based on the setting of the Stop Selection with Main Power Supply OFF
0
(Pn507) and turn it back to Servo ON state by turning ON the main power supply.
The Main power supply undervoltage (Alarm No.13.1) occurs. Stops the operation by the
1
alarm.
Pn509
Momentary Hold Time
Setting
70 to 2000
range
Set main power supply alarm detection time.
The main power supply OFF detection is disabled if this is set to 2000.
Pn510
Stop Selection for Alarm Detection
Setting
0 to 7
range
Select the stopping method at an alarm.
Refer to the Emergency Stop Operation at Alarms in "11-3 Alarms (P.11-6)".
Explanation of Set Values
Set
value
0
Dynamic brake operation
1
Free-run
2
Dynamic brake operation
3
Free-run
Operation A:
4
Operation B: Dynamic brake operation
Operation A:
5
Operation B: Free-run
Operation A:
6
Operation B: Dynamic brake operation
Operation A:
7
Operation B: Free-run
*1. Decelerating refers to a period between when the motor is running and when the motor speed reaches
30 r/min or less. Once the motor reaches a speed of 30 r/min or less and moves to the after stop
status, follow the subsequent operation based on the after stop status regardless of the motor speed.
*2. The motor may make a sudden motion.
*3. The Operation A and Operation B indicate whether to have an
emergency
normal stop by Operation B, when the alarm occurred does not support the
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
Unit
Unit
Unit
Stopping method during
*1
deceleration
Emergency
stop*3
Emergency
stop*3
Emergency
stop*3
Emergency
stop*3
stop takes place by the Operation A, when an
8-6 Extended Parameters
Default
setting
Explanation
Default
1 ms
setting
Default
setting
After stopping
Dynamic brake operation
Dynamic brake operation
Servo free
Servo free
Dynamic brake operation
Dynamic brake operation
Servo free
Servo free
emergency
emergency
All
Data
1
B
attribute
All
Data
70
C
attribute
All
Data
0
B
attribute
Error counter
*2
Clear
*2
Clear
*2
Clear
*2
Clear
*2
Clear
*2
Clear
*2
Clear
*2
Clear
stop at an error. An
stop alarm occurs. It is the
emergency
stop.
8-46
8