Pn419
Analog Monitor 2 Scale Setting
Setting
0 to 214748364
range
Set output gain for analog monitor 2.
Refer to the Analog Monitor 1 Scale Setting (Pn417) for the method to set this parameter.
Pn420
Unused
Setting
range
Pn421
Analog Monitor Output Selection
Setting
0 to 2
range
Select the analog monitor output voltage direction.
Set
value
0
1
2
This is the case when the Motor Speed is selected by the Analog Monitor 1 Selection or the Analog
Monitor 2 Selection, and the value 0 is set on the Analog Monitor 1 Scale Setting or the Analog
Monitor 2 Scale Setting (where 1 V = 500 r/min).
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
Unit
Pn418 monitor unit/V
Unit
Unit
Output range
10 to 10 V
0 to 10 V
0 to 10 V
(5 V as a center)
8-5 Interface Monitor Setting Parameters
Default
setting
Default
setting
Default
setting
Data output
Output voltage [V]
10 V
0 V
−5,000
−10 V
Output voltage [V]
10 V
−5,000
0 V
−10 V
Output voltage [V]
10 V
5 V
0 V
0
−2,500
−10 V
All
Data
0
A
attribute
All
Data
attribute
All
Data
0
A
attribute
Motor
speed
5,000 [r/min]
Motor
speed
5,000 [r/min]
Motor
speed
2,500 [r/min]
8-34
8