8-5 Interface Monitor Setting Parameters
Pn433
Positioning Completion Hold Time
Setting
range
Set the hold time for the case when the Positioning Completion Condition Selection (Pn432) is set
to 3.
When Positioning Completion Hold Time (Pn433) is set to 0, hold time becomes infinite and ON
status is held until the next position command comes in.
When a position command is entered during holding, the status changes to OFF.
Pn434
Zero Speed Detection
Setting
range
Set the output timing of the Zero speed detection output (ZSP) in rotation speed [r/min].
The Zero speed detection output (ZSP) becomes ON when the motor speed is lower than the set
value on this parameter.
The set value in this parameter is valid in both forward and reverse directions, regardless of the
actual motor rotation direction. The setting has a hysteresis of 10 r/min.
Refer to the Control Output Details in "3-1 Servo Drive Specifications (P.3-1)" for the Zero speed
detection output (ZSP).
8
OUTM1
8-37
0 to 30000
Unit
10 to 20000
Unit
Forward operation
Speed
(Pn434+10)r/min
(Pn434−10)r/min
Reverse operation
ON
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
Default
1 ms
setting
Default
r/min
setting
Full closing
Position
Data
0
A
attribute
All
Data
50
A
attribute