12- 2 Platform Ov erload R ec ov ery M ess age (s oftw are versi on B3 and later)
12-2
Platform Overload Recovery
Message (software version
B3 and later)
If the ground controls LCD screen displays Ovrld
Recovery, the emergency lowering system has
been used while the platform was overloaded.
Note: This message shall be cleared by a person
trained and qualified on the troubleshooting and
repair of this machine.
Note: Use the following illustration to identify the
description of each control button used in this
procedure.
1 LCD screen
2 up button
3 function enable button
4 down button
1
Turn the key switch to the ground controls
position and pull out the red Emergency Stop
button to the on position at the platform
controls.
2
Press and hold both the up and down buttons.
Pull out the red Emergency Stop button to the
on position at the ground controls.
Result: Tune speeds is showing in the LCD
screen.
Part No. 1272222
Platform Overload Components
3
Use the down button to scroll to select options.
4
Press the function enable button.
Result: Descent delay is showing in the LCD
screen.
5
Use the down button to scroll to overload.
6
Press and hold the function enable button for
5 seconds.
Result: A screen will appear asking for the
overload recovery passcode.
7
Press the buttons in the following sequence:
(down) (down) (up) (enable)
Result: The LCD screen displays cleared and
returns to the overload screen.
8
Use the down button to scroll to return to main
menu.
9
Press the function enable button.
Result: Select options is showing in the LCD
screen.
10 Push in the red Emergency stop button at the
ground controls.
GS-84 • GS-90