Level Sensor - Models Without Outriggers; How To Install And Calibrate The Level Sensor - Models Without Outriggers - Genie GS-3384 Service And Repair Manual

Scissor lift
Hide thumbs Also See for GS-3384:
Table of Contents

Advertisement

September 2016
5-4 Level Sensor - M odels without Outriggers
5-4
Level Sensor - Models without
Outriggers
The Electronic Control Module (ECM) is
programmed to deactivate the lift and drive
functions and activate an alarm when a signal is
received from the level sensor.
The tilt alarm sounds when the incline of the
chassis exceeds 2° to the side, or 3° to the front or
rear.
How to Ins tall and Cali brate the Level Sens or - M odels wi thout Outri ggers
How to Install and Calibrate the
Level Sensor - Models without
Outriggers
Tip-over hazard. Failure to install
or calibrate the level sensor as
instructed will compromise
machine stability and cause the
machine to tip over, resulting in
death or serious injury. Do not
install or calibrate the level
sensor other than specified in
this procedure.
Note: Perform this procedure with the machine on
a firm, level surface and the platform in the stowed
position. Use a digital level to confirm.
1
Remove the platform controls from the
platform.
If you are not installing a new level sensor,
proceed to step 9.
2
Push in the red Emergency Stop button to the
off position at the platform controls.
3
Remove the ground control panel retaining
fasteners and open the panel.
4
Locate the level sensor behind the ground
control panel.
Part No. 1272222
5
Tag and disconnect the wire harness from the
level sensor.
6
Remove the level sensor retaining fasteners.
Remove the level sensor from the machine.
7
Install the new level sensor onto the machine
with the "Y" on the level sensor base closest to
the steer end of the machine. Install and
tighten the level sensor retaining fasteners.

Level sensor - models without outriggers

1 chassis
2 level sensor
3 "X" indicator
4 "Y" indicator
8
Connect the wire harness to the level sensor.
9
Turn the key switch to platform control and pull
out the red Emergency Stop buttons to the on
position at both the ground and platform
controls.
GS-84 • GS-90
Service and Repair Manual
Ground Controls
Tip-over hazard. The tilt level
sensor must be installed with
the "Y" on the level sensor base
closest to the steer end of the
machine. Failure to install the
tilt level sensor as instructed
could result in the machine
tipping over causing death or
serious injury.
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs-3390Gs-4390Gs-5390

Table of Contents