15 Remove the AC outlet box and bracket from
the platform and lay them off to the side. Do
not disconnect the wiring.
Component damage hazard.
The AC power to platform wiring
can be damaged if it is kinked or
pinched.
Note: If your machine is equipped with an air line to
platform option, the air line must be disconnected
from the platform before removal.
16 Remove the pin retaining fasteners from the
platform centering links located under the
platform on both sides of the machine. Do not
remove the pins.
17 Place a rod through the platform centering link
pin and twist to remove the pin. Rest the
platform centering link on the scissor arm.
18 Repeat step 17 for the platform centering link
pivot pin on the other side of the machine.
19 Place a lifting strap from an overhead crane
under the platform at the steer end of the
machine for support. Do not apply any lifting
pressure.
Component damage hazard.
The platform railings can be
damaged if used to lift the
platform. Do not attach the lifting
straps to the platform railings.
Part No. 1272222
Platform Components
20 Place a lifting strap from a second overhead
crane under the platform at the non-steer end
of the machine for support. Do not apply any
lifting pressure.
21 Remove the pin retaining fasteners from each
platform slider block pivot pin. Do not remove
the pins.
22 Use a slide hammer to remove each platform
slider block pivot pin.
23 Secure the platform slider blocks to the
platform to prevent them from sliding out of the
channel when the platform is removed from
the machine.
24 Carefully lift the platform off of the machine
and place it on a structure capable of
supporting it.
GS-84 • GS-90
Service and Repair Manual
Component damage hazard.
The platform railings can be
damaged if used to lift the
platform. Do not attach the lifting
straps to the platform railings.
Crushing hazard. The platform
will fall when the platform slider
block pivot pins are removed if
not properly supported by the
overhead cranes.
Crushing hazard. The platform
will become unbalanced and fall
when it is removed from the
machine if not properly
supported by the overhead
cranes.
Bodily injury hazard. The
platform slider blocks could fall
out from under the platform if
they are not secured to the
platform.