Genie GS-3384 Service And Repair Manual page 137

Scissor lift
Hide thumbs Also See for GS-3384:
Table of Contents

Advertisement

September 2016
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN FMI
KWP
Description
175
2
738
Sensor oil temperature;
plausibility error
175
2
739
Sensor oil temperature;
plausibility error oil temperature
too high
175
3
743
Sensor error oil temperature;
signal range check high
175
4
744
Sensor error oil temperature;
signal range check low
190
0
389
Engine speed above warning
threshold (FOC-Level 1)
190
2
421
Offset angle between crank- and
camshaft sensor is too large
190
8
419
Sensor camshaft speed;
disturbed signal
190
8
422
Sensor crankshaft speed;
disturbed signal
190
11
390
Engine speed above warning
threshold (FOC-Level 2)
190
12
420
Sensor camshaft speed; no
signal
190
12
423
Sensor crankshaft speed; no
signal
190
14
391
Engine speed above warning
threshold (Overrun Mode)
190
14
1222
Camshaft- and Crankshaft speed
sensor signal not available on
CAN
411
0
791
Physical range check high for
differential pressure Venturiunit
(EGR)
411
1
792
Physical range check low for
differential pressure Venturiunit
(EGR)
411
3
795
Sensor error differential pressure
Venturiunit (EGR); signal range
check high
411
4
381
Physical range check low for
EGR differential pressure
411
4
796
Sensor error differential pressure
Venturiunit (EGR); signal range
check low
Part No. 1272222
Deutz D 2.9 L4 Engine Fault Codes
SPN FMI
412
3
412
4
520
9
597
2
624
3
624
4
624
5
624
12
630
12
630
12
630
12
639
14
651
3
651
4
651
5
652
3
652
4
652
5
653
3
653
4
653
5
GS-84 • GS-90
Service and Repair Manual
KWP
Description
1007
Sensor error EGR cooler
downstream temperature; signal
range check high
1008
Sensor error EGR cooler
downstream temperature; signal
range check low
306
Timeout Error of
CAN-Receive-Frame TSC1TR;
Setpoint
49
Break lever mainswitch and
break lever redundancy switch
status not plausible
971
SVS lamp; short circuit to batt.
972
SVS lamp; short circuit to grd.
969
SVS lamp; open load
970
SVS lamp; powerstage over
temperature
376
Access error EEPROM memory
(delete)
377
Access error EEPROM memory
(read)
378
Access error EEPROM memory
(write)
84
CAN-Bus 0 "BusOff-Status"
580
Injector 1 (in firing order); short
circuit
586
High side to low side short circuit
in the injector 1 (in firing order)
568
Injector 1 (in firing order);
interruption of electric connection
581
Injector 2 (in firing order); short
circuit
587
High side to low side short circuit
in the injector 2 (in firing order)
569
Injector 2 (in firing order);
interruption of electric connection
582
Injector 3 (in firing order); short
circuit
588
High side to low side short circuit
in the injector 3 (in firing order)
570
Injector 3 (in firing order);
interruption of electric connection
125

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs-3390Gs-4390Gs-5390

Table of Contents