Displaying And Maintaining Port Isolation; Port Isolation Configuration Example; Network Requirements; Configuration Procedure - H3C S7500E-X Configuration Manual

Layer 2 lan switching
Hide thumbs Also See for H3C S7500E-X:
Table of Contents

Advertisement

Displaying and maintaining port isolation

Execute display commands in any view.
Task
Display isolation group information.

Port isolation configuration example

Network requirements

As shown in
LAN users Host A, Host B, and Host C are connected to GigabitEthernet 1/0/1, GigabitEthernet
1/0/2, and GigabitEthernet 1/0/3 on the device, respectively.
The device connects to the Internet through GigabitEthernet 1/0/4.
Configure the device to provide Internet access for the hosts, and isolate them from one another at
Layer 2.
Figure 17 Network diagram

Configuration procedure

# Create isolation group 2.
<Device> system-view
[Device] port-isolate group 2
# Assign GigabitEthernet 1/0/1, GigabitEthernet 1/0/2, and GigabitEthernet 1/0/3 to isolation group
2.
[Device] interface gigabitethernet 1/0/1
[Device-GigabitEthernet1/0/1] port-isolate enable group 2
[Device-GigabitEthernet1/0/1] quit
[Device] interface gigabitethernet 1/0/2
[Device-GigabitEthernet1/0/2] port-isolate enable group 2
[Device-GigabitEthernet1/0/2] quit
Figure
17:
Command
display port-isolate group [ group-number ]
55

Advertisement

Table of Contents
loading

Table of Contents