Trunk Promiscuous Port Configuration Example - H3C S7500E-X Configuration Manual

Layer 2 lan switching
Hide thumbs Also See for H3C S7500E-X:
Table of Contents

Advertisement

Secondary VLAN ID: 2-3
VLAN ID: 5
VLAN type: Static
Private VLAN type: Primary
Route interface: Not configured
Description: VLAN 0005
Name: VLAN 0005
Tagged ports:
Untagged ports:
GigabitEthernet1/0/2
GigabitEthernet1/0/3
GigabitEthernet1/0/5
VLAN ID: 2
VLAN type: Static
Private VLAN type: Secondary
Route interface: Not configured
Description: VLAN 0002
Name: VLAN 0002
Tagged ports:
Untagged ports:
GigabitEthernet1/0/2
GigabitEthernet1/0/5
VLAN ID: 3
VLAN type: Static
Private VLAN type: Secondary
Route interface: Not configured
Description: VLAN 0003
Name: VLAN 0003
Tagged Ports:
Untagged Ports:
GigabitEthernet1/0/3
GigabitEthernet1/0/5
The output shows that:
The promiscuous port GigabitEthernet 1/0/5 is an untagged member of primary VLAN 5 and
secondary VLANs 2 and 3.
The host port GigabitEthernet 1/0/2 is an untagged member of primary VLAN 5 and secondary
VLAN 2.
The host port GigabitEthernet 1/0/3 is an untagged member of primary VLAN 5 and secondary
VLAN 3.

Trunk promiscuous port configuration example

Network requirements
As shown in
None
None
None
Figure
46, configure the private VLAN feature to meet the following requirements: