Oki B 4100 Maintenance Manual page 83

Facsimile transceiver
Hide thumbs Also See for B 4100:
Table of Contents

Advertisement

T.F.
Item
No.
16
T1 (RX), timeout value
17
T2, timeout value
18
DIS bit32
19
Error criterion
20
Off-hook bypass
21
NL equalizer
22
Modem attenuator
40055101TH Rev.4
Table 2.9.1 (4/6) Service Personnel Initial Settings
T1 (RX), timeout value (later)
Registers the time duration (in seconds) for which the
fax waits for the remote station's answer of individual
country's specification. This timer starts after the DIS
is transmitted, and checked this timer by the transmis-
sion timing signal. If T1 times out, the fax disconnects
the line.
* Selects the 3 digit timer
010 to 255 sec selectable. (in one second steps)
T2, timeout value (layer)
Registers the time duration (in seconds) for which the
fax detects the EOL interval during reception of phase
C. The fax disconnects the line when EOL can not
detect within T2 timer.
* Selects the 3 digit timer
001 to 255 selectable. (in 100ms steps)
For example: 060 x 100 ms =6 s
Specifies whether to transmit a bit 32 in DIS.
ON :
OFF:
Note:
Registers the threshould value whether to transmit
RTN or MCF signal when the error occurs in received
data.
00% to 99% selectable. (in one percent steps)
Switches the function of maintaining communication
without hooking up the telephone set in normal test-
ing etc.
ON :
OFF:
Selects equalization for the following cable lengths:
0 km/1.8 km/3.6 km/ 7.2 km selectable.
Note:
Adjusts the attenuation (dB) for the message send
signal power level.
Adjusting value is 0 to 15 dB in one dB steps.
Since the maximum send signal power level (dB) of
the fax is at 0 dB, you can select 0 dB to -15 dB in one
dB steps for the send signal power level.
Specifications
Transmits a bit 32
Disable
When occurring a communication error at
receive by the old fax machine.
Enable
Disable
Relative to 1700Hz for length of 0.4mm
diameter cable.
0 to 15 dB. selectable
Default
83 /

Advertisement

Table of Contents
loading

Table of Contents