Oki B 4100 Maintenance Manual page 389

Facsimile transceiver
Hide thumbs Also See for B 4100:
Table of Contents

Advertisement

1.
Block diagram
The circuit diagram shown on page 5/12 consists of the following functions:
IC6 (A/D converter)
30 V/24 V conversion circuit
Connector CN5 that provides an interface between R44 board and CIS (contact image sensor).
Figure A3.1.5 shows the related signals and block diagram of CIS.
2.
Function
One-line picture data is read in the sequence from the scanning unit (CIS) as SIG signal (analog
data) to A/D converter (analog/digital converter) of IC6. After conversion from analog data to 6-
bit digital signal (SDATA0 - SDATA5) under the control of IC6, this picture data is sent to
IOGA3 (input/output gate array). Here, the picture data undergoes various kinds of picture
processings.
Sensor interface signal output from IOGA3
LEDON : LED on/off control signal
SNSCLK : Scanning sensor drive clock (714.286 kHz)
MISP
ADCLK : Sampling clock for A/D converter (714.286 kHz)
A3.1.6
R44 Circuit Diagram (Page 6/12)
IC2
IOGA
SDATA0 - SDATA5
IC6
A/D converter
30 V/24 V conversion
30V
circuit
Figure A3.1.5 Related Signals and Block Diagram of CIS (contact image sensor)
40055101TH Rev.4
: Scanning synchronous signal (5 msec)
R44
CN5
Transistor
VLED
LEDON
TR9/TR10
GLED
MISP
DCK (714.286 kHz)
SIG
+5 V
-8 V
0 VA
24 V
CIS (contact image sensor)
VLED (+24V)
10
9
GLED
6
MISP
Shift register & analog switches
8
DCK
1
SIG
3
+5 V
4
-8 V
2, 5, 7
0 VA
LEDs array
Rod lens array
sensor
1728 bit (216 mm)
Amplifier
389 /