4.2.3.6 Lower Base, Motor Assembly, Back-up Roller, Transfer Roller

(1)
Disassembly procedure
1)
Lower Base, Motor Assembly
a)
First, carry out the disassembly
procedure up to the point of the
Fusing Unit removal.
(Refer to sub-item 4.2.3.5.)
b)
Disconnect the two connectors
(CN3 and CN4 on the MCNT
board).
c)
Remove the Lower Base by re-
moving the seven screws 1 to
3.
d)
Press up and hold the two latches
while removing the Motor As-
sembly out.
2)
Back-up Roller, Transfer Roller
a)
After removing the Lower Base,
remove the spring.
b)
Lift the left side of the Back-up
Roller and pull it out leftwards.
40055101TH Rev.4
Screw 1
Lower Base
Screw 2
Screw 2
Motor Ass'y
Reset lever (L and R)
Screw 3
(FX-050VP-C4-023)
Latches
(FX050-C4-024)
Back-up Roller
Upper Cover
Spring
(FX050-C4-022)
194 /