3)
Stacker Cover
a)
Disconnect the flat cable.
b)
Remove the Copy Stacker by
pressing inward the two latches
on it from the two reset levers.
c)
Remove the Copy Stacker by
spreading it from the lower base.
4)
Fusing Unit
a)
Remove the Fusing Unit by re-
moving the four screws 2.
5)
Manual Feed Assembly
a)
First, carry out the disassembly
procedure up to the point of Main
Cover removal. (Refer to sub-
section 4.2.3.2)
b)
Remove the Manual Feed Assem-
bly by pressing inward the two
retainers.
(2)
Reassembly procedure
Reverse the disassembly procedures.
40055101TH Rev.4
Copy Stacker
Reset lever
Fusing Unit
Screws 2
(FX050-C4-022)
Manual Feed
Retainer
Assembly
Flat cable
Reset lever
(FX050-C4-021)
Screws 2
Retainer
(FX-050VP-C4-020)
193 /