Oki B 4100 Maintenance Manual page 283

Facsimile transceiver
Hide thumbs Also See for B 4100:
Table of Contents

Advertisement

Troubleshooting flow chart 11:
Periodic abnormal printing
Check the fax control side.
40055101TH Rev.4
Yes
1.44" (36.6 mm)
period?
No
Yes
1.98" (50.3 mm)
period?
No
Yes
2.63" (66.8 mm)
period?
No
Yes
0.81" (20.6 mm)
period?
No
Yes
0.81" (20.6 mm)
period?
No
Yes
1.71" (43.4 mm)
period?
No
Yes
2.46" (62.5 mm)
period?
No
Yes
1.98" (50.3 mm)
period?
No
Developing roller (inside EP unit)
failure.
Replace or clean the EP unit.
EP drum (inside EP unit)
failure.
Replace the EP unit.
Tonner supply roller (inside the EP unit)
failure.
Replace the EP unit.
Charging roller (inside the EP unit)
failure.
Replace the EP unit.
Cleaning roller (inside the EP unit )
failure.
Replace the EP unit.
Replace the transfer roller.
Heater roller (inside the fuser unit)
failure.
Replace the fuser unit.
Replace the Back-up roller.
283 /

Advertisement

Table of Contents
loading

Table of Contents