6.14

System Reset

1.
Purpose
To clear or initialize the following data:
(a) Location data
(b) Configuration data (default)
2.
Procedure
Operations:
Press SELECT FUNCTION key, COPY key twice.
(In case of no message in the memory)
Enter 3.
To bring the LCD up to the desired message,
press
key and
Note:
ALL DATA CLEAR is to clear or
initialize (a) to (b).
40055101TH Rev.4
key.
ARE YOU SURE ?
YES( )
Data CLR
The display shows:
TECH. PROGRAMMING
YES( /1-4)
3
3:SYSTEM RESET
YES( )
NO( /1-4)
1:ALL DATA CLR
YES( )
NO( /1-3)
2:LOCATION DATA CLR
YES( )
NO( /1-3)
3:CONFIG. DATA CLR
YES( )
NO( /1-3)
NO( )
CLEAR
End of data clear
NO( )
1
2
3
4