3)
High-voltage and medium-voltage control
High voltages are activated by IOGA3 and generated by the high-voltage circuit inside the
power supply unit. The CH (charge) voltage of about -1.35 kV is used for the charge roller.
The TR1/TR2 (transfer) voltage of about +3.5 kV/-0.75 kV is used for the transfer roller.
Medium voltages are activated by IOGA3 and generated by the medium-voltage circuit
inside the power supply unit. The SB1/SB2 (toner supply) voltage of about +0 V/-450 V is
used for the toner supply roller. The DB1/DB2 (developping) voltage of about +300 V/-
300 V is used for the developing roller. The CB (cleaning) voltage of about +400V is used
for the cleaning roller.
Figure A3.2.19 shows high/medium voltages control.
* Signals used to control the high/medium-voltages are listed below.
M17
IOGA3
DBON1
DBON2
DBPWM
TR1PWM
CHPWM
TR2PWM
40055101TH Rev.4
Signal Name
CHPWM
P.W.M : CH is output.
DB1ENB
"1": + ive polarity voltage of DB1/SB1 is output.
DB2ENB
"1": - ive polarity voltage of DB2/SB2/CB is output.
TR1PWM
P.W.M : TR1 is output.
TR2PWM
P.W.M : TR2 is output.
DBPWM
P.W.M : DB/SB/CB is output.
1VP/2VP (Power supply unit)
CH
High-voltage
TR1/TR2
generation
circuit
Medium-
voltage
CB
generation
circuit
DB1/DB2
SB1/SB2
Figure A3.2.19 High/Medium Voltage Control
Description
Contact assy.
Charge roller
EP drum
Cleaning roller
Transfer roller
Developing roller