Chapter 7
[1]
5) Turn the handle [1] by 180 deg, and hold the handle [1] and the grip [2] to
pull out the process unit [3] until it stops.
[2]
6) Press the push button [1], and hold the grip [2] to open the ITB unit [3]
upward.
[2]
7) Secure the ITB unit [1] in place with the tip-resistant arm [2] (secure in
the lower slot of the 2).
7-44
[1]
F-7-76
[3]
[1]
F-7-77
[1]
[3]
F-7-78
Do not touch the ITB. If the ITB is scratched, it may cause the pickup fault
or degradation of the print quality.
In case the print quality is degraded due to touching the ITB, clean the ITB
with soft and dry cloth.
If the print quality is not improved, execute the following:
[Additional Functions] > [Adjustment/Cleaning] > [Cleaning inside Main
Unit] > [Start]
[1]
8) By pressing the ITB lock lever [1], remove the ITB unit [2] in the direction
of the arrow.
[1]
[2]

7.9.7 Transfer Cleaning Unit

7.9.7.1 Before Removing the Transfer Cleaner Unit

/ / / / iR C3380i / iR C3380 / iR C2880i / iR C2880
1) Remove the ITB unit. (page 7-43)[Removing the ITB Unit]

7.9.7.2 Removing the Transfer Cleaner Unit

/ / / / iR C3380i / iR C3380 / iR C2880i / iR C2880
1) Remove the transfer cleaner unit [1].
- 4 screws [2]
[2]
F-7-79
[1]
F-7-80
0014-2604