Transfer Cleaning Unit; Before Removing The Transfer Cleaner Unit; Removing The Transfer Cleaner Unit - Canon iR C2880 Series Service Manual

Hide thumbs Also See for iR C2880 Series:
Table of Contents

Advertisement

Chapter 7
[2]
[1]
F-7-80
8) Fix the ITB unit [1] with the tip-resistant arm [2] (Fix in the lower one of
the 2 grooves).
9) Cover the drum cartridges with the drum protective sheet [3].
Cover it with drum protective sheet [3] immediately after fixing the ITB unit
[1].
If time elapses, photosensitive drum is exposed to light and will be deterio-
rated.
[1]
[3]
F-7-81
Points to note when closing the ITB unit
When closing the ITB unit [1], be sure to remove the tip-resistant arm [2]. If
closing the ITB unit with the tip-resistant arm fixed, the tip-resistant arm
may be broken.
10) Remove the ITB unit [2] in the direction of the arrow while pressing the
ITB lock lever [1].
Points to note when removing the ITB unit
Hold the grip [1] when removing the ITB unit.
7-48
Place the removed ITB unit with the surface facing the photosensitive drum
downward.
In the case that the surface facing the photosensitive drum is placed upward,
the ITB lock lever [1] may be broken.
[3]
[2]

7.9.7 Transfer Cleaning Unit

7.9.7.1 Before Removing the Transfer Cleaner Unit

iR C3380i / iR C3380 / iR C2880i / iR C2880 / iR C3580 / iR C3580i / iR
C3080 / iR C3080i
1) Remove the ITB unit. (page 7-47)[Removing the ITB Unit]

7.9.7.2 Removing the Transfer Cleaner Unit

iR C3380i / iR C3380 / iR C2880i / iR C2880 / iR C3580 / iR C3580i / iR
C3080 / iR C3080i
1) Remove the 4 screws [1].
[1]
F-7-82
[1]
F-7-83
[1]
[1]
[2]
F-7-84
0014-2604
0014-2605