Field Service Ver. 1.0 Jul. 2007
6.3.59
Fusing motor (M5)
1. Remove the PWB box.
See P.138
[2]
[1]
[1]
[1]
[2]
A02EF2C170DA
[3]
A02EF2C171DA
2. Remove five screws [1], and remove
the bracket [2].
3. Remove four screws [1], disconnect
the connector [2], and remove the
fusing motor [3].
6. Other
153