6. Other
[3]
[4]
[2]
[1]
100
[3]
[4]
[1]
9J06F2C578DA
A02EF2C079DA
Field Service Ver. 1.0 Jul. 2007
2. Push the PH unit [1] along the right
side line of PH unit installation plate
all the way and fit it into the plate
spring [2].
3. Make sure that the two bosses [3] at
front and rear side of the PH unit fit
in the locating hole [4].
4. Reinstall the stopper [1].
NOTE
• When reinstalling the stopper, use
care so that both ends of the stop-
per will not open but stay parallel as
shown on the left.
Keep using the stopper after once
stretched out may cause uneven
pitch or other image troubles.