Sign In
Upload
Manuals
Brands
DAIKIN Manuals
Air Conditioner
Super Multi NX FDXS60CVMB
DAIKIN Super Multi NX FDXS60CVMB Manuals
Manuals and User Guides for DAIKIN Super Multi NX FDXS60CVMB. We have
8
DAIKIN Super Multi NX FDXS60CVMB manuals available for free PDF download: Service Manual, Service Manual Field, Operation Manual, Installation Manual
Daikin Super Multi NX FDXS60CVMB Service Manual (501 pages)
E-Series, F-Series, G-Series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 28.58 MB
Table of Contents
Table of Contents
4
Introduction
8
Safety Cautions
8
Used Icons
12
Part 1 List of Functions
13
Functions
14
Cooling Only - Indoor Unit
14
Cooling Only - Outdoor Unit
20
Heat Pump - Indoor Unit
21
Heat Pump - Outdoor Unit
28
Part 2 Specifications
29
Cooling Only - Indoor Unit
30
Cooling Only - Outdoor Unit
41
Heat Pump - Indoor Unit
43
Heat Pump - Outdoor Unit
57
Part 3 Printed Circuit Board Connector Wiring Diagram
61
Indoor Unit
62
Wall Mounted Type
62
Floor Standing Type
71
Floor / Ceiling Suspended Dual Type
73
Duct Connected Type
75
Ceiling Mounted Cassette Type
77
Ceiling Mounted Built-In Type
81
Ceiling Suspended Type
86
Remote Controller
88
Wired Remote Controller
88
Wireless Remote Controller
90
Outdoor Unit
92
Part 4 Function and Control
95
Function of Indoor Unit (RA Models)
96
Temperature Control
96
Frequency Principle
96
Operation Starting Control
98
Airflow Direction Control
99
Fan Speed Control for Indoor Units
101
Program Dry Operation
102
Automatic Operation
103
Thermostat Control
104
NIGHT SET Mode
106
ECONO Operation
107
HOME LEAVE Operation
108
2-Area INTELLIGENT EYE Operation
109
INTELLIGENT EYE Operation
111
Inverter POWERFUL Operation
112
Other Functions
114
Function of Indoor Unit (SA Models)
116
Drain Pump Control
116
Thermostat Sensor in Remote Controller
118
Freeze Prevention Control
120
Hot Start Control (in Heating Operation Only)
121
Function of Thermistor
122
Control Specification
124
Mode Hierarchy
124
Frequency Control
125
Controls at Mode Changing / Start-Up
128
Discharge Pipe Temperature Control
129
Input Current Control
130
Freeze-Up Protection Control
130
Heating Peak-Cut Control
131
Outdoor Fan Control
131
Liquid Compression Protection Function
132
Defrost Control
132
Low Hz High Pressure Limit
133
Electronic Expansion Valve Control
133
Pressure Equalizing Control
135
Malfunctions
138
Part 5 Operation Manual
140
System Configuration
141
RA Indoor Unit
142
FTXG, CTXG Series - ARC466A1
142
Name of Parts
144
Fan Operation
146
Operating Conditions
147
FTXS, FVXS Series - ARC452A1, A3
166
Names of Parts
172
Opening the Front Panel
173
ATXS, FLK(X)S, FDK(X)S Series - ARC433B67, B68, B69, B76
202
SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series
224
Brc1D528
224
Brc1E51A7
239
Operation Mode
242
Automatic Operation Mode
242
Program Dry
249
Key Lock
253
Airflow Direction
260
Ventilation Mode
264
Timer Settings
264
Schedule Timer
266
Holiday Setting
270
Convenient Functions
275
Contrast Adjustment
275
Clock Setting
278
Setting the Clock
278
Useful Information
283
Brc7E530W/531W, Brc7F532F/533F, Brc7Ea63W/66
284
Operation Range
287
Operation Procedure
288
Part 6 Service Diagnosis
296
Troubleshooting with LED
298
Indoor Unit
298
Outdoor Unit
300
Problem Symptoms and Measures
301
Service Check Function
302
RA Indoor Unit - F(C)TXG, FTXS, ATXS, FVXS, FLK(X)S, FDK(X)S Series
302
SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series
311
Code Indication on Remote Controller
318
RA Indoor Unit - F(C)TXG, FTXS, ATXS, FVXS, FLK(X)S
318
FDK(X)S Series
318
SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series
318
RA Indoor Unit - F(C)TXG, FTXS, ATXS, FVXS, FLK(X)S, FDK(X)S Series
318
Outdoor Unit
319
Troubleshooting for RA Indoor Unit - F(C)TXG, FTXS, ATXS, FVXS, FLK(X)S, FDK(X)S Series
320
Indoor Unit PCB Abnormality
320
Freeze-Up Protection Control or Heating Peak-Cut Control
321
Fan Motor or Related Abnormality
323
Thermistor or Related Abnormality (Indoor Unit)
326
Front Panel Open / Close Fault (FTXG and CTXG Series)
327
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
328
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
330
Troubleshooting for SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series
331
Indoor Unit PCB Abnormality
331
Drain Water Level System Abnormality
332
Fan Motor or Related Abnormality
334
Swing Motor Lock (FHQ Series)
336
Drain System Abnormality
337
Thermistor or Related Abnormality
338
Remote Controller Thermistor Abnormality
340
Signal Transmission Error
341
(Between Indoor Unit and Remote Controller)
341
Signal Transmission Error (between Indoor Unit and Remote Controller)
341
Signal Transmission Error
342
(Between MAIN Remote Controller and SUB Remote Controller)
342
Signal Transmission Error (between MAIN Remote Controller and SUB Remote Controller)
342
Field Setting Abnormality
343
Troubleshooting for Outdoor Unit
345
Anti-Icing Function
345
Outdoor Unit PCB Abnormality
347
OL Activation (Compressor Overload)
348
Compressor Lock
349
DC Fan Lock
350
Input Overcurrent Detection
351
Discharge Pipe Temperature Control
352
High Pressure Control in Cooling
353
Compressor Sensor System Abnormality
355
Position Sensor Abnormality
357
CT or Related Abnormality
359
Thermistor or Related Abnormality (Outdoor Unit)
361
Electrical Box Temperature Rise
363
Radiation Fin Temperature Rise
365
Output Overcurrent Detection
367
Refrigerant Shortage
369
Low-Voltage Detection or Over-Voltage Detection
371
Signal Transmission Error (on Outdoor Unit PCB)
372
Anti-Icing Function in Other Rooms / Unspecified Voltage (between Indoor and Outdoor Units)
373
Check
374
Thermistor Resistance Check
374
Fan Motor Connector Check
375
Hall IC Check
375
Power Supply Waveform Check
375
Electronic Expansion Valve Check
376
Four Way Valve Performance Check
377
Inverter Unit Refrigerant System Check
377
Inverter Checker" Check
378
Rotation Pulse Check on the Outdoor Unit PCB
379
Installation Condition Check
380
Discharge Pressure Check
380
Outdoor Fan System Check
381
Capacitor Voltage Check
381
Power Module Check
381
Part 7 Removal Procedure
382
Outdoor Unit - 50~75 Class
383
Removal of Outer Panels
383
Removal of Electrical Box
387
Removal of Pcbs
395
Removal of Outdoor Fan / Fan Motor
400
Removal of Sound Blankets
402
Removal of Coils / Thermistors
406
Removal of Distributor
409
Removal of Four Way Valve
410
Removal of Compressor
411
Outdoor Unit - 80/90 Class
413
Removal of Outer Panels
413
Removal of Electrical Box
429
Removal of Pcbs
435
Removal of Fan Motor
439
Removal of Coils / Thermistors
440
Removal of Sound Blankets
446
Removal of Compressor
449
Advertisement
Daikin Super Multi NX FDXS60CVMB Service Manual (398 pages)
Brand:
Daikin
| Category:
Air Conditioner
| Size: 14.81 MB
Table of Contents
Table of Contents
3
Introduction
8
Safety Cautions
8
Caution in Repair
8
Cautions Regarding Products after Repair
9
Inspection after Repair
10
Using Icons
11
Using Icons List
11
Part 1 List of Functions
12
List of Functions
13
Part 2 Specifications
20
Specifications
21
Outdoor Units
21
BP Unit
22
Indoor Units
23
Ceiling Mounted Cassette Type
31
Part 3 Printed Circuit Board Connector Wiring Diagram
34
Printed Circuit Board Connector Wiring Diagram
35
Outdoor Unit RMXS 112/140/160 E7V3B
35
Branch Provider Unit
40
Wall Mounted Type 20/25/35/50 Class - D Series
41
Wall Mounted Type 20/25/35 Class - C Series
44
Wall Mounted Type 50/60/71 Class - E(B) Series
46
Duct Connected Type
48
Floor / Ceiling Suspended Dual Type
50
Floor Standing Type
53
Ceiling Mounted Cassette 600×600 Type
56
Ceiling Suspended Type
58
Part 4 Refrigerant Circuit
60
Refrigerant Circuit
61
Outdoor Units
61
Refrigerant Circuit Part
61
BP Units
63
Functional Parts Layout
64
Outdoor Units
64
Refrigerant Flow for each Operation Mode
65
Cooling Operation
65
Heating Operation
66
Cooling Oil Return Operation
67
Heating Oil Return Operation & Defrost Operation
68
Part 5 Function
70
Operation Mode
71
Basic Control
72
Normal Operation
72
Compressor PI Control
73
Electronic Expansion Valve PI Control
76
Cooling Operation Fan Control
77
Special Control
78
Startup Control
78
Oil Return Operation
79
Defrosting Operation
81
Pump-Down Residual Operation
82
Restart Standby
82
Stopping Operation
83
Protection Control
84
High Pressure Protection Control
84
Low Pressure Protection Control
85
Discharge Pipe Protection Control
86
Inverter Protection Control
87
Freeze-Up Protection Control
88
Dew Condensation Prevention Control
89
Other Control
90
Demand Operation
90
Heating Operation Prohibition
90
BP Unit Control
91
BP Unit Command Conversion
91
BP Unit Electronic Expansion Valve Control
92
Full Closing of Electronic Expansion Valves
93
SH Control in Cooling Operation
94
SC Control in Heating Operation
95
Heat Exchanger Isothermal Control in Heating Operation
95
Indoor Unit (RA Models)
96
Power-Airflow Dual Flaps, Wide Angle Louvers and Auto-Swing
96
Fan Speed Control for Indoor Units
97
Programme Dry Function
98
Automatic Operation
99
Thermostat Control
100
Night Set Mode
101
ECONO Mode
102
Intelligent Eye
103
HOME LEAVE Operation
105
Inverter POWERFUL Operation
106
Other Functions
107
Indoor Unit (Skyair Models)
109
Function Outline
109
Electric Function Parts
110
Function Details
111
Part 6 Test Operation
122
Test Operation
123
Procedure and Outline
123
Check Operation
126
Outdoor Unit PCB Layout
128
Field Setting
129
Field Setting from Outdoor Unit
129
Detail of Setting Mode
138
Field Setting for Skyair Indoor Unit
147
Explanation
147
Field Setting
148
Initial Setting Contents
149
Local Setting Mode Number
150
Detailed Explanation of Setting Modes
151
Centralized Group No. Setting
155
Maintenance Mode Setting
156
Test Operation and Field Setting for RA Indoor Unit
157
Test Operation from the Remote Control
157
Jumper Settings
158
Part 7 System Configuration
160
System Configuration
161
Operation Instructions
161
Instruction
162
RMXS Series
162
Wall Mounted, Duct, Floor/Ceiling, Floor Standing Type
163
Safety Precautions
164
Installation Site
165
Electrical Work
165
Names of Parts
166
Indoor Unit
169
Outdoor Unit
170
Remote Control
171
To Set the Clock
186
To Change the Air Flow Rate Setting
188
Adjusting the Air Flow Direction
189
Air Flow Selection
198
Powerful Operation
199
Outdoor Unit Silent Operation
200
Econo Operation
201
Intelligent Eye Operation
204
Timer Operation
210
To Use on Timer Operation
211
To Combine on Timer and off Timer
211
Note for Multi System
212
Priority Room Setting
213
Care and Cleaning
214
Air Filter
215
Before a Long Idle Period
216
Front Panel
217
Cleaning the Air Filter
223
Front Grille
230
Troubleshooting
233
These Cases Are Not Troubles
233
Ceiling Mounted Cassette Type
238
Temperature Setting
243
Fan Speed Control
243
Ceiling Suspended Type
249
Operation Range
252
Air Flow Direction Adjust
254
Part 8 Troubleshooting
260
Caution for Diagnosis
262
Troubleshooting with the Operation Lamp (RA Indoor Unit)
262
Troubleshooting with the LED on the Skyair Indoor Unit
263
Troubleshooting with the LED on the Outdoor Unit
264
Troubleshooting with the LED on the BP Unit
265
Service Check Function
266
RA Indoor Unit Infrared Remote Control
266
Skyair Indoor Unit INSPECTION/TEST Button
270
Skyair Indoor Unit Wired Remote Control
271
Skyair Indoor Unit Infrared Remote Control
272
Service Check Function
273
Sky Air Indoor Unit Error Codes and LED Indication
274
Malfunction Code Indication by Outdoor Unit PCB
275
List of Malfunction Code
279
Troubleshooting for RA Indoor Unit
281
Indoor Unit PCB Abnormality
281
Freeze-Up Protection Control or High Pressure Control
282
Fan Motor or Related Abnormality
284
Thermistor or Related Abnormality (Indoor Unit)
287
Shutter Drive Motor / Shutter Limit Switch Abnormality
288
Check
289
Thermistor Resistance Check
290
Hall IC Check
291
Troubleshooting for Skyair Indoor Unit
292
Indoor Unit PCB Abnormality
292
Malfunction of Drain Water Level System (Float Type)
293
Malfunction of Drain System
295
Indoor Unit Fan Motor Lock
296
Malfunction of Indoor Unit Fan Motor
297
Swing Flap Motor Malfunction / Lock
299
Malfunction of Capacity Setting
301
Malfunction of Heat Exchanger Thermistor (R2T)
302
Malfunction of Heat Exchanger Thermistor (R3T)
303
Malfunction of Suction Air Thermistor
304
Malfunction of Remote Control Thermistor
305
Transmission Error (between Indoor Unit and Remote Control)
306
Transmission Error (between Main and Sub Remote Control)
307
Malfunction of Field Setting Switch
308
Check
309
Troubleshooting for BP Unit
311
Malfunction of Electronic Expansion Valve
311
Faulty BP Unit PCB
312
Faulty BP Liquid or Gas Pipe Thermistor
313
Transmission Error between Indoor Unit and BP Unit
314
Transmission Error between Outdoor Unit and BP Unit
316
Check
317
Troubleshooting for Outdoor Unit
318
Faulty Outdoor Unit PCB
318
Actuation of High Pressure Switch
319
Actuation of Low Pressure Sensor
321
Compressor Motor Lock
323
Malfunction of Outdoor Unit Fan Motor
324
Malfunction of Moving Part of Electronic Expansion Valve (Y1E, Y3E)
325
Abnormal Discharge Pipe Temperature
327
Refrigerant Overcharged
328
Malfunction of Thermistor for Outdoor Air (R1T)
329
Malfunction of Discharge Pipe Thermistor (R2T)
330
Malfunction of Thermistor (R3T, R5T) for Suction Pipe1, 2
331
Malfunction of Thermistor (R4T) for Outdoor Unit Heat Exchanger
332
Malfunction of Thermistor (R7T) for Outdoor Unit Liquid Pipe
333
Malfunction of Subcooling Heat Exchanger Thermistor (R6T)
334
Malfunction of High Pressure Sensor
335
Malfunction of Low Pressure Sensor
336
Malfunction of PCB
337
Malfunction of Inverter Radiating Fin Temperature Rise
338
Inverter Compressor Abnormal
339
Inverter Current Abnormal
340
Inverter Start up Error
341
Malfunction of Transmission between Inverter and Control PCB
342
High Voltage of Capacitor in Main Inverter Circuit
343
Malfunction of Inverter Radiating Fin Temperature Rise Sensor
344
Faulty Combination of Inverter and Fan Driver
345
Low Pressure Drop Due to Refrigerant Shortage or Electronic Expansion Valve Failure
346
Power Supply Insufficient or Instantaneous Failure
348
Check Operation Not Executed
350
Malfunction of Transmission between Indoor Units and Outdoor Units
351
Malfunction of Transmission between Remote Control and Indoor Unit
353
Malfunction of Transmission between Main and Sub Remote Controls
354
Malfunction of Transmission between Indoor and Outdoor Units in the same System
355
Excessive Number of Indoor Units
357
Address Duplication of Central Remote Control
358
Malfunction of Transmission between Central Remote
359
Controller and Indoor Unit
359
System Is Not Set yet
361
Malfunction of System, Refrigerant System Address Undefined
362
Daikin Super Multi NX FDXS60CVMB Service Manual (355 pages)
super multi nx
Brand:
Daikin
| Category:
Air Conditioner
| Size: 15.37 MB
Table of Contents
Table of Contents
3
Introduction
6
Safety Cautions
6
Used Icons
10
Part 1 List of Functions
12
List of Functions
13
Cooling Only Models
13
Heat Pump Models
18
Part 2 Specifications
24
Indoor Units - Cooling Only
25
Outdoor Units - Cooling Only
34
Indoor Units - Heat Pump
35
Outdoor Units - Heat Pump
46
Part 3 Printed Circuit Board Connector Wiring Diagram
48
Printed Circuit Board Connector Wiring Diagram
49
Wall Mounted Type
49
Duct Connected Type
58
Floor / Ceiling Suspended Dual Type
60
Floor Standing Type
63
Ceiling Suspended Type
65
Outdoor Units
67
Part 4 Function and Control
70
Main Functions
71
Frequency Principle
71
Power-Airflow Dual Flaps, Wide Angle Louvers and Auto-Swing
73
Operation Starting Control
75
Fan Speed Control for Indoor Units
76
Programme Dry Function
77
Automatic Operation
78
Thermostat Control
79
Night Set Mode
80
ECONO Mode
81
INTELLIGENT EYE (Wall Mounted Type Only)
82
HOME LEAVE Operation
84
Inverter POWERFUL Operation
85
Other Functions
86
Function of Main Structural Parts
88
Main Structural Parts
88
Function of Thermistor
89
Control Specification
93
Mode Hierarchy
93
Frequency Control
94
Controls at Mode Changing / Start-Up
97
Compressor Protection Function
98
Discharge Pipe Control
99
Input Current Control
99
Freeze-Up Protection Control
100
Heating Peak-Cut Control
100
Fan Control
101
Liquid Compression Protection Function 2
101
Defrost Control
102
Electronic Expansion Valve Control
103
Malfunctions
107
Forced Operation Mode
108
Wiring-Error Check
109
Additional Function
111
Part 5 Operation Manual
114
System Configuration
115
Operation Instructions
115
Instruction
116
FTK(X)S, FTXG, CTXG, FDK(X)S, FLK(X)S Series
116
Safety Precautions
117
FVXS Series
192
Air Flow Selection
203
FHQ Series
223
Temperature Setting
229
Fan Speed Control
229
Part 6 Service Diagnosis
236
Caution for Diagnosis
237
Troubleshooting with Operation Lamp
237
Problem Symptoms and Measures
239
Service Check Function
240
Check Method 1
240
Check Method 2
242
Code Indication on the Remote Control
244
Error Codes and Description of Fault
244
Troubleshooting
245
Indoor Units
245
Outdoor Units
246
Indoor Unit PCB Abnormality
247
Freeze-Up Protection Control or High Pressure Control
248
Fan Motor or Related Abnormality
250
Thermistor or Related Abnormality (Indoor Unit)
253
Front Panel Open / Close Fault
254
Signal Transmission Error (between Indoor and Outdoor Unit)
255
Unspecified Voltage (between Indoor and Outdoor Units)
257
Freeze-Up Protection Control
258
Outdoor Unit PCB Abnormality
260
OL Activation (Compressor Overload)
261
Compressor Lock
262
DC Fan Lock
263
Input over Current Detection
264
Discharge Pipe Temperature Control
266
High Pressure Control in Cooling
267
Compressor Sensor System Abnormality
269
Position Sensor Abnormality
271
CT or Related Abnormality
272
Thermistor or Related Abnormality (Outdoor Unit)
274
Sienbe12
275
Electrical Box Temperature Rise
276
Radiation Fin Temperature Rise
278
Output over Current Detection
280
Insufficient Gas
282
Low-Voltage Detection or Over-Voltage Detection
284
Signal Transmission Error (on Outdoor Unit PCB)
285
Anti-Icing Function in Other Rooms / Unspecified Voltage
286
(Between Indoor and Outdoor Units)
286
Anti-Icing Function in Other Rooms / Unspecified Voltage (between Indoor and Outdoor Units)
286
Check
287
How to Check
287
Electronic Expansion Valve Check
288
Four Way Valve Performance Check
289
Installation Condition Check
291
Discharge Pressure Check
292
Power Supply Waveforms Check
293
Capacitor Voltage Check
294
Power Transistor Check
294
Main Circuit Electrolytic Capacitor Check
295
Hall IC Check
296
Part 7 Removal Procedure
298
Outdoor Unit
299
Removal of the Panels and Plates
299
Removal of the Electrical Box
303
Removal of the PCB
311
Removal of the Propeller Fan / Fan Motor
317
Removal of the Sound Blanket
319
Removal of Electronic Expansion Valve Coil, Four Way Valve Coil and Thermistor
323
Removal of the Distributor
326
Removal of the Four Way Valve
327
Removal of the Compressor
328
Advertisement
Daikin Super Multi NX FDXS60CVMB Service Manual Field (150 pages)
C-Series Inverter Pair Duct Connected Type
Brand:
Daikin
| Category:
Air Conditioner
| Size: 3.68 MB
Table of Contents
Table of Contents
3
Part 1 List of Functions
3
Part 3 Printed Circuit Board Connector Wiring Diagram
3
Part 5 Operation Manual
3
Introduction
6
Safety Cautions
6
Used Icons
10
Part 1 List of Functions
11
Functions
12
Part 2 Specifications
15
Specifications
16
Cooling Only
16
Heat Pump
19
Part 3 Printed Circuit Board Connector Wiring Diagram
22
Printed Circuit Board Connector Wiring Diagram
23
Indoor Unit
23
Outdoor Unit
25
Part 4 Function and Control
27
Main Functions
28
Temperature Control
28
Frequency Principle
28
Fan Speed Control for Indoor Units
30
Program Dry Operation
31
Automatic Operation
32
Thermostat Control
33
NIGHT SET Mode
34
HOME LEAVE Operation
35
Inverter POWERFUL Operation
36
Other Functions
37
Function of Thermistor
38
Control Specification
39
Mode Hierarchy
39
Frequency Control
40
Controls at Mode Changing / Start-Up
42
Discharge Pipe Temperature Control
43
Input Current Control
44
Freeze-Up Protection Control
45
Heating Peak-Cut Control
45
Outdoor Fan Control
46
Liquid Compression Protection Function
46
Defrost Control
47
Electronic Expansion Valve Control
48
Malfunctions
51
Part 5 Operation Manual
52
System Configuration
53
Operation Manual
54
Remote Controller
54
AUTO · DRY · COOL · HEAT · FAN Operation
55
To Change the Air Flow Rate Setting
56
POWERFUL Operation
57
OUTDOOR UNIT QUIET Operation
58
HOME LEAVE Operation
59
TIMER Operation
61
To Use on Timer Operation
62
To Combine on Timer and off Timer
62
Part 6 Service Diagnosis
63
Caution for Diagnosis
64
Troubleshooting with LED
64
Problem Symptoms and Measures
65
Service Check Function
66
Troubleshooting
69
Error Codes and Description
69
Indoor Unit PCB Abnormality
70
Freeze-Up Protection Control or Heating Peak-Cut Control
71
Fan Motor (AC Motor) or Related Abnormality
73
Thermistor or Related Abnormality (Indoor Unit)
74
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
75
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
76
Outdoor Unit PCB Abnormality
77
OL Activation (Compressor Overload)
78
Compressor Lock
79
DC Fan Lock
80
Input Overcurrent Detection
81
Four Way Valve Abnormality
82
Discharge Pipe Temperature Control
84
High Pressure Control in Cooling
85
Compressor System Sensor Abnormality
86
Position Sensor Abnormality
87
CT or Related Abnormality
89
Thermistor or Related Abnormality (Outdoor Unit)
91
Electrical Box Temperature Rise
93
Radiation Fin Temperature Rise
95
Output Overcurrent Detection
97
Refrigerant Shortage
99
Low-Voltage Detection or Over-Voltage Detection
101
Signal Transmission Error (on Outdoor Unit PCB)
102
Check
103
How to Check
103
Four Way Valve Performance Check
104
Thermistor Resistance Check
105
Installation Condition Check
106
Discharge Pressure Check
106
Outdoor Fan System Check
107
Power Supply Waveforms Check
107
Capacitor Voltage Check
108
Power Module Check
108
Hall IC Check
111
Part 7 Removal Procedure
112
Outdoor Unit
113
Removal of Outer Panels
113
Removal of Outdoor Fan / Fan Motor
117
Removal of Electrical Box
121
Removal of PCB
126
Removal of Sound Blanket / Thermistors
129
Removal of Four Way Valve
131
Removal of Electronic Expansion Valve
132
Removal of Compressor
133
Part 8 Trial Operation and Field Settings
136
Pump down Operation
137
Forced Cooling Operation Mode
138
Daikin Super Multi NX FDXS60CVMB Service Manual (149 pages)
C-Series Inverter Pair Duct Connected Type
Brand:
Daikin
| Category:
Air Conditioner
| Size: 1.86 MB
Table of Contents
Table of Contents
4
Introduction
7
Safety Cautions
7
Used Icons
11
Part 1 List of Functions
13
Functions
14
Part 2 Specifications
17
Specifications
18
Cooling Only
18
Heat Pump
21
Part 3 Printed Circuit Board Connector Wiring Diagram
24
Printed Circuit Board Connector Wiring Diagram
25
Indoor Unit
25
Outdoor Unit
27
Part 4 Function and Control
29
Main Functions
30
Temperature Control
30
Frequency Principle
30
Fan Speed Control for Indoor Units
32
Program Dry Operation
33
Automatic Operation
34
Thermostat Control
35
NIGHT SET Mode
36
HOME LEAVE Operation
37
Inverter POWERFUL Operation
38
Other Functions
39
Function of Thermistor
40
Control Specification
41
Mode Hierarchy
41
Frequency Control
42
Controls at Mode Changing / Start-Up
44
Discharge Pipe Temperature Control
45
Input Current Control
46
Freeze-Up Protection Control
47
Heating Peak-Cut Control
47
Outdoor Fan Control
48
Liquid Compression Protection Function
48
Defrost Control
49
Electronic Expansion Valve Control
50
Malfunctions
53
Forced Operation Mode
54
Part 5 Operation Manual
55
System Configuration
56
Operation Manual
57
Remote Control
57
Auto Dry Cool Heat Fan Operation
58
AUTO · DRY · COOL · HEAT · FAN Operation
58
To Change the Air Flow Rate Setting
59
POWERFUL Operation
60
OUTDOOR UNIT QUIET Operation
61
HOME LEAVE Operation
62
TIMER Operation
64
To Use on Timer Operation
65
To Combine on Timer and off Timer
65
Part 6 Service Diagnosis
66
Caution for Diagnosis
67
Troubleshooting with LED
67
Problem Symptoms and Measures
68
Service Check Function
69
Troubleshooting
72
Error Codes and Description
72
Indoor Unit PCB Abnormality
73
Freeze-Up Protection Control or Heating Peak-Cut Control
74
Fan Motor (AC Motor) or Related Abnormality
76
Thermistor or Related Abnormality (Indoor Unit)
77
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
78
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
79
Outdoor Unit PCB Abnormality
80
OL Activation (Compressor Overload)
81
Compressor Lock
82
DC Fan Lock
83
Input Overcurrent Detection
84
Four Way Valve Abnormality
85
Discharge Pipe Temperature Control
87
High Pressure Control in Cooling
88
Compressor System Sensor Abnormality
89
Position Sensor Abnormality
90
CT or Related Abnormality
92
Thermistor or Related Abnormality (Outdoor Unit)
94
Electrical Box Temperature Rise
96
Radiation Fin Temperature Rise
98
Output Overcurrent Detection
100
Refrigerant Shortage
102
Low-Voltage Detection or Over-Voltage Detection
104
Signal Transmission Error (on Outdoor Unit PCB)
105
Check
106
How to Check
106
Four Way Valve Performance Check
107
Thermistor Resistance Check
108
Installation Condition Check
109
Discharge Pressure Check
109
Outdoor Fan System Check
110
Power Supply Waveforms Check
110
Capacitor Voltage Check
111
Power Module Check
111
Hall IC Check
112
Part 7 Removal Procedure
113
Outdoor Unit
114
Removal of Outer Panels
114
Removal of Outdoor Fan / Fan Motor
118
Removal of Electrical Box
122
Removal of PCB
127
Removal of Sound Blanket / Thermistors
130
Removal of Four Way Valve
132
Removal of Electronic Expansion Valve
133
Removal of Compressor
134
Daikin Super Multi NX FDXS60CVMB Service Manual (147 pages)
Inverter Pair Duct Connected Type C-Series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 3.76 MB
Table of Contents
Table of Contents
3
Part 1 List of Functions
3
Part 3 Printed Circuit Board Connector Wiring Diagram
3
Introduction
6
Safety Cautions
6
Used Icons
10
Part 1 List of Functions
11
Functions
12
Part 2 Specifications
15
Specifications
16
Cooling Only
16
Heat Pump
19
Part 3 Printed Circuit Board Connector Wiring Diagram
22
Printed Circuit Board Connector Wiring Diagram
23
Indoor Unit
23
Outdoor Unit
25
Part 4 Function and Control
27
Main Functions
28
Temperature Control
28
Frequency Principle
28
Fan Speed Control for Indoor Units
30
Program Dry Operation
31
Automatic Operation
32
Thermostat Control
33
NIGHT SET Mode
34
HOME LEAVE Operation
35
Inverter POWERFUL Operation
36
Other Functions
37
Function of Thermistor
38
Control Specification
39
Mode Hierarchy
39
Frequency Control
40
Controls at Mode Changing / Start-Up
42
Discharge Pipe Temperature Control
43
Input Current Control
44
Freeze-Up Protection Control
45
Heating Peak-Cut Control
45
Outdoor Fan Control
46
Liquid Compression Protection Function
46
Defrost Control
47
Electronic Expansion Valve Control
48
Malfunctions
51
Forced Operation Mode
52
Part 5 Operation Manual
53
System Configuration
54
Operation Manual
55
Remote Controller
55
AUTO · DRY · COOL · HEAT · FAN Operation
56
To Change the Air Flow Rate Setting
57
POWERFUL Operation
58
OUTDOOR UNIT QUIET Operation
59
HOME LEAVE Operation
60
TIMER Operation
62
To Use on Timer Operation
63
To Combine on Timer and off Timer
63
Part 6 Service Diagnosis
64
Caution for Diagnosis
65
Troubleshooting with LED
65
Problem Symptoms and Measures
66
Service Check Function
67
Troubleshooting
70
Error Codes and Description
70
Indoor Unit PCB Abnormality
71
Freeze-Up Protection Control or Heating Peak-Cut Control
72
Fan Motor (AC Motor) or Related Abnormality
74
Thermistor or Related Abnormality (Indoor Unit)
75
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
76
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
77
Outdoor Unit PCB Abnormality
78
OL Activation (Compressor Overload)
79
Compressor Lock
80
DC Fan Lock
81
Input Overcurrent Detection
82
Four Way Valve Abnormality
83
Discharge Pipe Temperature Control
85
High Pressure Control in Cooling
86
Compressor System Sensor Abnormality
87
Position Sensor Abnormality
88
CT or Related Abnormality
90
Thermistor or Related Abnormality (Outdoor Unit)
92
Electrical Box Temperature Rise
94
Radiation Fin Temperature Rise
96
Output Overcurrent Detection
98
Refrigerant Shortage
100
Low-Voltage Detection or Over-Voltage Detection
102
Signal Transmission Error (on Outdoor Unit PCB)
103
Check
104
How to Check
104
Four Way Valve Performance Check
105
Thermistor Resistance Check
106
Installation Condition Check
107
Discharge Pressure Check
107
Outdoor Fan System Check
108
Power Supply Waveforms Check
108
Capacitor Voltage Check
109
Power Module Check
109
Hall IC Check
110
Part 7 Removal Procedure
111
Outdoor Unit
112
Removal of Outer Panels
112
Removal of Outdoor Fan / Fan Motor
116
Removal of Electrical Box
120
Removal of PCB
125
Removal of Sound Blanket / Thermistors
128
Removal of Four Way Valve
130
Removal of Electronic Expansion Valve
131
Removal of Compressor
132
Part 8 Trial Operation and Field Settings
135
DAIKIN Super Multi NX FDXS60CVMB Operation Manual (28 pages)
Inverter
Brand:
DAIKIN
| Category:
Air Conditioner
| Size: 2.51 MB
Table of Contents
Operation Manual
1
Table of Contents
2
Safety Precautions
3
Installation Site
4
Electrical Work
4
Names of Parts
5
Outdoor Unit
6
Indoor Unit
6
Remote Controller
7
Preparation before Operation
8
AUTO · DRY · COOL · HEAT · FAN Operation
11
To Change the Air Flow Rate Setting
12
POWERFUL Operation
13
OUTDOOR UNIT QUIET Operation
14
HOME LEAVE Operation
15
TIMER Operation
17
To Use on Timer Operation
18
To Combine on Timer and off Timer
18
Note for Multi System
19
Care and Cleaning
21
Before a Long Idle Period
22
Trouble Shooting
23
Check Again
24
Call the Service Shop Immediately
25
Disposal Requirements
25
Important Information Regarding the Refrigerant Used
25
Fault Diagnosis
26
Daikin Super Multi NX FDXS60CVMB Installation Manual (15 pages)
R410A Split Series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 1.84 MB
Table of Contents
Safety Precautions
3
Choosing a Site
4
Preparations before Installation
5
Indoor Unit Installation
7
Outdoor Unit Installation
8
Refrigerant Piping Work
8
Drain Piping Work
10
Installing the Duct
11
Trial Operation and Testing
13
Advertisement
Related Products
DAIKIN FDXS60F2VEB
DAIKIN FDXS60C7VMB
Daikin FDXS60CVMA
Daikin FDXS60LVMA
Daikin SUPER MULTI NX FDXS09LVJU
Daikin FDXS12DVJU
DAIKIN Super Multi NX FDXS25EAVMB
DAIKIN Super Multi NX FDXS50CVMB
DAIKIN Super Multi NX FDXS35EAVMB
DAIKIN FDXS25F2VEB
DAIKIN Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More DAIKIN Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL