Check - Daikin E-Series Service Manual

Hide thumbs Also See for E-Series:
Table of Contents

Advertisement

Troubleshooting for SkyAir Indoor Unit

5.15 Check

Check No. 01
Check for Fan Motor Connector (Power Supply Line)
(1) Turn the power supply off.
With the relay connector disconnected, measure the resistance between UVW phases of the
connector (3 cores) at the motor side, then make sure that the resistance between each phase
is balanced and not short-circuited.
298
Red
U
White
V
Black
W
Measure the resistance between
each phase.
(S2675)
SiENBE18-621