Night Set Mode - Daikin FTKS20D3VMW Service Manual

Super multi nx
Table of Contents

Advertisement

SiENBE12-713
1.8

Night Set Mode

When the OFF timer is set, the Night Set circuit automatically activates.
The Night Set circuit maintains the airflow setting made by users.
The Night Set
The Night Set circuit continues heating or cooling the room at the set temperature for the first
Circuit
one hour, then automatically raises the temperature setting slightly in the case of cooling, or
lowers it slightly in the case of heating, for economical operations. This prevents excessive
heating in winter and excessive cooling in summer to ensure comfortable sleeping conditions,
and also conserves electricity.
Cooling
Operation
In case of FTXG25-35E, CTXG50E, FTK(X)S20-50D, FVXS25-50F the temperature rises once.
Heating
Operation
Function and Control
0.5°C
1 hour
30 minutes
+0.5°C
Timer operation
temperature schift
Night Set Circuit ON
When outside temperature is normal and
room temperature is at set temperature.
When outside temperature is high (27°C or higher).
0.5°C
1 hour
+0.5°C
Timer operation
temperature schift
Night Set Circuit ON
Thermostat
setting
Timer operation
Night Set Circuit ON
Temperature
setting +1°C
0.5°C
Temperature
setting +0,5°C
Temperature
setting
Operation stops
at the set hours
+0.5°C temperature schift
Temperature setting remains the same
Temperature
setting +0.5°C
Temperature
setting
Temperature stops
at the set hours
(R4421)
2°C
1 hour later
(R1362)
Main Functions
(R1361)
69