1.4

Outdoor Units - Heat Pump

Model
Cooling Capacity
Power Consumption
Running Current
Casing Color
Type
Compressor
Model
Motor Output
Model
Refrigerant Oil
Charge
Type
Refrigerant
Charge
m³/min
Air Flow Rates
cfm
Type
Motor Output
Fan
Running Current
Power Consumption
Starting Current
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation Sound
Sound Power
Liquid
Piping Connection
Gas
Drain
Heat Insulation
No. of Wiring Connection
Max. Interunit Piping Length
Amount of Additional Charge
Max. Installation Height Difference
Drawing No.
Note:
1. The data are based on the conditions shown in the table below.
Specifications
kW
W
A
W
L
kg
H
M
L
H
M
L
W
A
H: 0.20 / M: 0.16 / L: 0.10
W
H: 70 / M: 58 / L: 36
A
mm
mm
kg
kg
dBA
dBA
mm
mm
mm
m
m
g/m
m
m
Cooling
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB
Outdoor ; 7°CDB/6°CWB
4MXS68F2V1B
Cooling
Ivory White
Hermetically Sealed Swing Type
2YC45DXD
1,380
FVC50K
0.65
R-410A
2.6
52.7
49.4
43.5
1,861
1,744
1,536
Propeller
53
6.2
735×936×300
797×992×390
58
63
48
61
φ
6.4 × 4
φ
, φ
9.5 × 2
12.7 × 2
φ
18.0
Both Liquid and Gas Pipes
3 for Power Supply, 4 for Interunit Wiring
60 (for Total of Each Room)
25 (for One Room)
20 (30m or more)
15 (between Indoor Unit and Outdoor Unit)
7.5 (between Indoor Units)
3D056404
Heating
Piping Length
Indoor ; 20°CDB
5m
Specifications
50Hz 230V
Heating
46.4
44.5
16.3
1,638
1,571
576
H: 0.16 / M: 0.14 / L: 0.03
H: 55 / M: 48 / L: 10
49
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
35