Introduction to the WS4/WS4 LX FRUs

Cables and Toroids

Cables and Toroids

This section presents the cables available for the WS4 and adds the WS4 LX.
Considering the original AB28 series system board connector changes, three LCD
panels and the recent introduction of the WS4 LX System board, a total of four LCD
interface cables and two backlight interface cables are available. The WS4 LX system
board (ABRD86) uses the same LCD and backlight cables as the WS4 Rev I (AB28-I)
or ABRD36-B system boards. The table below summarizes the LCD and backlight
cable part numbers, based on the system board type, revision and the Samsung or
Sharp CD panels.
System
Board
AB28-F
AB28-G
AB28-I
ABRD36-B
ABRD86
Each cable is listed individually in the following pages.
Cable, Assembly LCD Display, REV F/G, BD, WS4 - P/N 300331-204
The cable shown in Figure 1-7 connects between the EOL Samsung LCD LVDS
Board and system boards AB28-F and AB28-G. This cable is not compatible with a
Sharp LCD.
Figure 1-7: Samsung LCD Cable for AB28-F and AB28-G System Boards
1-12
Sharp LCD
Samsung
(LG41,
LCD
LG61)
300331-204
300331-202
300331-201
300331-203
300331-201
300331-203
N/A
300331-203
Workstation 4 and 4 LX Field Service Guide
Backlight
Inverter
300331-103
300331-200
300331-200
300331-200