Lcc; Rs232 - Micros Systems Workstation 4 LX Service Manual

Table of Contents

Advertisement

Connector and Cable Diagrams
IO Panel Connectors

LCC(-)

Figure A-2. The LCC(-) configuration, allows the RS422-A port to connect to a
MICROS LCC, RCC, or NetCC over RS422 twisted-pair cable. This configuration is
rarely used and is not supported by the WS4 LX System Board.
Figure A-2: The RS422-A Port in LCC(-) mode (WS4 Only)

RS232

The RS422-A and RS422-B ports include a basic Transmit/Receive RS232 interface
on pins 1 and 6. Hardware handshaking lines are not available. This configuration is
available on the WS4 and WS4 LX System Boards and is shown in below.
Figure A-3: The RS422-A and RS422-B Ports Configured for RS232
Workstation 4 and 4 LX Field Service Guide
A-3