12. Fasten the NCU unit into place from the
bottom with two M3 × 06 chrome binding
screws.
13. Connect the three connectors from the NCU
board to the corresponding connectors on the
fax board, as follows:
• Speaker 2-pin connector → CN7
• NCU board connector → CN3
• Battery connector → CN6
14. Connect the three positive connectors on the
power board to the corresponding connectors
on the auxiliary power source PCB, as
follows.
• White positive connector → TB1 (white)
• Green positive connector → TB2 (green)
• White positive connector → TB3
15. Connect the FAX-PCB-Power cable to
connector on the auxiliary power source PCB.
16. Fit the catch on the auxiliary power unit into
the mount hole in the copier, and fasten the
auxiliary power unit into place with one M3 ×
06 chrome binding screw.
NCU board
connector
Speaker
2-pin connecto
Battery
connector
Figure 1-3-70
White positive
connector
Green positive
White positive
connector
connector
Figure 1-3-71
Catch
Mount hole
Figure 1-3-72
NCU board
NCU unit
M3 × 06 chrome
binding screws
Auxiliary power
source PCB
FAX-PCB-Power
cable
Connector
M3 × 06 chrome
binding screw