1-6-3 Optical section
(1) Detaching and refitting the exposure lamp
Replace the exposure lamp as follows.
Procedure
1. Remove the original cover or the DF.
2. Remove the upper right cover, upper front
cover, upper rear cover and contact glass.
3. Move the mirror 1 frame to the cutouts of the
machine.
Caution: When moving the mirror 1 frame, do
not touch the exposure lamp nor the inverter
PCB.
4. Remove the two screws holding the metal
plate on the rear of the machine and then the
plate.
5. Detach the exposure lamp connector from the
inverter PCB.
6. Remove the two screws holding the exposure
lamp and then the lamp.
7. Replace the exposure lamp and refit all the
removed parts.
Contact glass
Figure 1-6-26
Figure 1-6-27
Connector
Figure 1-6-28
2BH/J
Upper rear cover
Upper right cover
Metal plate
Exposure lamp
1-6-15