Code
Contents
C4010
Polygon motor steady-state problem
• The polygon motor rotation is not sta-
ble for 600 ms after the polygon mo-
tor rotation has been stabilized.
C4200
BD steady-state problem
• The VTC detects a BD error for 600
ms after the polygon motor rotation
has been stabilized.
C5300
Broken cleaning lamp wire
While the cleaning lamp is on, the bro-
ken cleaning lamp wire detection signal
is detected for 2 s continuously.
C6000
Broken fixing heater wire
• The fixing temperature does not in-
crease for 40 s after the fixing heaters
have been turned on for warming up.
• The fixing temperature remains below
50 °C/122 °F for 10 s continuously
after the fixing heaters have been
turned on during stabilization.
C6020
Abnormally high fixing unit thermis-
tor temperature
• The fixing temperature exceeds 230
°C/446 °F for 10 s.
Causes
Check procedures/corrective measures
Poor contact in
Reinsert the connector. Also check for con-
the polygon motor
tinuity within the connector cable. If none,
connector termi-
remedy or replace the cable.
nals.
Defective polygon
Replace the LSU (see page 1-6-20).
motor.
Defective power
Check if 24 V DC is supplied to CN2-1 on
source PCB.
the main PCB. If not, replace the power
source PCB.
Defective main
Check if 24 V DC is output from CN8-10 on
PCB.
the main PCB. If not, replace the main
PCB.
Defective laser
Replace the LSU (see page 1-6-20).
diode.
Defective polygon
Replace the LSU (see page 1-6-20).
motor.
Defective main
Replace the main PCB and check for cor-
PCB.
rect operation.
Defective cleaning
Replace the cleaning lamp.
lamp.
Defective main
Replace the main PCB and check for cor-
PCB.
rect operation.
Poor contact in
Check the connection of connector CN10
the fixing unit
on the main PCB and the continuity across
thermistor con-
the connector terminals. Repair or replace
nector terminals.
if necessary.
Fixing unit ther-
Check and reinstall if necessary.
mistor installed
incorrectly.
Fixing unit ther-
Check for continuity. If none, replace the
mostat triggered.
fixing unit thermostat.
Fixing unit heater
Check and reinstall if necessary.
M or S installed
incorrectly.
Broken fixing unit
Check for continuity. If none, replace the
heater M or S
fixing unit heater M or S (see page 1-6-38).
wire.
Measure the resistance. If it is 0 Ω, replace
Shorted fixing unit
thermistor.
the fixing unit thermistor.
Broken fixing unit
Replace the power source PCB.
heater control cir-
cuit on the power
source PCB.