Kyocera Mita KM-3530 Service Manual page 192

Hide thumbs Also See for KM-3530:
Table of Contents

Advertisement

2BH/J
(18) Image center does not
align with the original
center.
Causes
1. Misadjusted center line of image printing.
2. Misadjusted scanner center line.
3. Original placed incorrectly.
(19) Image is not
square.
Causes
1. Laser scanner unit positioned incorrectly.
2. Image scanning unit positioned incorrectly.
1-5-50
Causes
1. Misadjusted center line of image printing.
2. Misadjusted scanner center line.
3. Original placed incorrectly.
Readjust the center line of image printing (see page 1-6-19).
Readjust the scanner center line (see page 1-6-37).
Place the original correctly.
Causes
1. Laser scanner unit positioned incorrectly.
2. Image scanning unit positioned incorrectly.
Adjust the installation position of the laser scanner unit
(see page 1-6-30).
Adjust the installation position of the image scanning unit
(see page 1-6-30).
Check procedures/corrective measures
Check procedures/corrective measures