Kyocera Mita KM-3530 Service Manual page 218

Hide thumbs Also See for KM-3530:
Table of Contents

Advertisement

2BH/J
(2) Detaching and refitting the scanner wires
Take the following procedure when the scanner wires are broken or to be replaced.
Caution:
After replacing the scanner wire, make a test copy and check the copy image. If the image is incorrect, perform the
adjustments (see pages 1-6-25 to 31).
(2-1) Detaching the scanner wires
Procedure
1. Remove the exposure lamp (see page 1-6-
19).
2. Remove the upper left cover and scanner left
cover.
3. Remove the inverter wire guide plate and
then the wire from the inverter PCB.
4. Remove the screw holding each of the front
and rear wire retainers and then remove the
mirror 1 frame from the scanner unit.
1-6-16
Front wire retainer
Scanner left cover
Upper left cover
Figure 1-6-29
Inverter wire guide plate
Inverter wire
Figure 1-6-30
Mirror 1 frame
Rear wire retainer
Figure 1-6-31