2BH/J-3
Maintenance
item No.
U960
Outputting the machine used circumstances list
Description
Outputs machine used circumstances list and clears the data.
Purpose
To check the machine operation situation. Also to clear the data.
Method
Press the start key.
Outputting the list
1. Select OUTPUT.
2. Press the start key to output the list.
Clearing
1. Select COUNT CLEAR.
2. Press the start key to clear the count.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U990
Checking/clearing the time for the exposure lamp to light
Description
Displays, clears or changes the accumulated time for the exposure lamp to light.
Purpose
To check duration of use of the exposure lamp. Also to clear the accumulated time for the lamp after
replacement.
Method
Press the start key. The accumulated time of illumination for the exposure lamp is displayed in minutes.
Clearing
1. Press the reset key.
2. Press the start key. The accumulated time is cleared, and the screen for selecting a maintenance item No.
is displayed.
Setting
1. Enter a six-digit accumulated time using the numeric keys.
2. Press the start key. The time is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the accumulated time, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.