(8) Adjusting magnification of the scanner in the main scanning direction
Perform the following adjustment if the magnification in the main scanning direction is not correct.
U065
U053
(main scanning
(P. 1-4-12)
direction)
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Also, perform "(9) Adjusting magnification of the scanner in the auxiliary scanning direction" (page 1-6-28) and "(11)
Adjusting the scanner center line" (page 1-6-30) after this adjustment.
Procedure
Enter maintenance mode.
Enter "065" using the numeric keys.
Press the start key.
Select "MAIN SCAN ADJ"
(main scanning direction).
Press the interrupt key.
Place an original and press
the start key to make a test copy.
Is the image correct?
Press the stop/clear key to
exit maintenance mode.
U065
(auxiliary scanning
direction) (P. 1-6-28)
Start
No
Yes
End
U067
(P. 1-6-30)
Original
Copy
example
Figure 1-6-54
Press the start key.
The new setting
is stored.
For copy example 1, increase the
value using the cursor up key.
For copy example 2, decrease the
value using the cursor down key.
Setting range: –25 – +25
Initial setting: 0
Changing the value by 1 changes
the magnification by 0.1%.
Increasing the value makes
the image wider, and decreasing it
makes the image narrower.
2BH/J
Copy
example 2