2BH/J
Code
Contents
C6050
Abnormally low fixing unit thermis-
tor temperature
• The fixing temperature remains below
120 °C/248 °F for 10 s.
C6410
Fixing unit connector insertion prob-
lem
• Absence of the fixing unit is detected
continuously for 1500 ms while there
is no error on the copier.
C6420
Broken fixing unit thermistor wire
• The fixing temperature remains at 0
°C/32 °F for 30 s continuously when
the fixing heater is on.
C7300
Toner sensor problem
• While the toner container sensor is
on, the toner sensor in the developing
unit does not turn on after the toner
sensor turns off and toner is replen-
ished from the toner container.
C7400
Image formation unit connector in-
sertion problem
• Absence of the image formation unit
is detected continuously for 1500 ms
while there is no error on the copier.
1-5-36
Causes
Check procedures/corrective measures
Poor contact in
Check the connection of connector CN10
the fixing unit
on the main PCB and the continuity across
thermistor con-
the connector terminals. Repair or replace
nector terminals.
if necessary.
Measure the resistance. If it is ∞ Ω, replace
Broken fixing unit
thermistor wire.
the fixing unit thermistor.
Fixing unit ther-
Check and reinstall if necessary.
mistor installed
incorrectly.
Fixing unit ther-
Check for continuity. If none, replace the
mostat triggered.
fixing unit thermostat.
Fixing unit heater
Check and reinstall if necessary.
M or S installed
incorrectly.
Broken fixing unit
Check for continuity. If none, replace the
heater M or S
fixing unit heater M or S.
wire.
Fixing unit con-
Reinsert the fixing unit connector if neces-
nector inserted
sary.
incorrectly.
Defective fixing
Replace the fixing unit.
unit connector.
Poor contact in
Check the connection of connector CN10
the fixing unit
on the main PCB and the continuity across
thermistor con-
the connector terminals. Repair or replace
nector terminals.
if necessary.
Measure the resistance. If it is ∞ Ω, replace
Broken fixing unit
thermistor wire.
the fixing unit thermistor.
Defective toner
Replace the toner sensor.
sensor.
Poor contact in
Reinsert the connector. Also check for con-
the toner sensor
tinuity within the connector cable. If none,
connector termi-
remedy or replace the cable.
nals.
Defective toner
Replace the toner container sensor.
container sensor.
Defective toner
Replace the toner container.
container.
Image formation
Reinsert the image formation unit connec-
unit connector in-
tor if necessary.
serted incorrectly.
Defective image
Replace the image formation unit.
formation unit
connector.
Remarks
*: Optional