Kyocera Mita KM-3530 Service Manual page 517

Hide thumbs Also See for KM-3530:
Table of Contents

Advertisement

Maintenance
item No.
U609
Setting the T2 time-out time
(cont.)
The T2 time-out time decides the following.
• From CFR signal output to image data reception
• From image data reception to the next signal reception
• In ECM, from RNR signal detection to the next signal reception
1. Change the setting using the numeric keys.
Description
T2 time-out time
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the Ta time-out time
In the fax/telephone auto select mode, sets the time to continue ringing an operator through the connected
telephone after receiving a call as a fax machine (see figure 1-3-1). A fax signal is received within the Ta set
time, or the fax mode is selected automatically when the time elapses. In fax/telephone auto select mode,
change the setting when fax reception is unsuccessful or a telephone fails to receive a call.
1. Change the setting using the numeric keys.
Description
Ta time-out time
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the Tb1 time-out time
In the fax/telephone auto select mode, sets the time to start sending the ring back tone after receiving a call as
a fax machine (see figure 1-3-1). In fax/telephone auto select mode, change the setting when fax reception is
unsuccessful or a telephone fails to receive a call.
1. Change the setting using the numeric keys.
Description
Tb1 time-out time
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the Tb2 time-out time
In the fax/telephone auto select mode, sets the time to start ringing an operator through the connected
telephone after receiving a call as a fax machine (see figure 1-3-1). In the fax/telephone auto select mode,
change the setting when fax reception is unsuccessful or a telephone fails to receive a call.
1. Change the setting using the numeric keys.
Description
Tb2 time-out time
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Description
Setting range Initial setting Change in value per step
1 to 255
69
Setting range Initial setting
1 to 255 s
30
Tb1
Tb2
Figure 1-3-1 Ta/Tb1/Tb2 time-out time
Setting range Initial setting Change in value per step
1 to 255
20
Setting range Initial setting Change in value per step
1 to 255
80
100 ms
Ta
100 ms
100 ms
3CM
1-3-17