Transmit Metering Data
Service Options
Maintenance Interface [OFF / ON]
via RPC
Telnet Server
Diagnostics
<get diagnostics file>
Setup GUI – SYSTEM – Setup
Program Configuration
Program Labels
Program 1
Program 2
Current Sync Source Status
Source
Sample Rate
Show detailed status
[OFF / ON]
metering data will be streamed via UDP protocol. In order not to receive
such data by external applications you may disable it.
For administrative use to enable communication with factory tools.
[ON / OFF]
Enables a telnet server to connect to the consol interface via
Telnet (IP port 21).
Pressing this soft button will start the assembly of a diagnostics file.
The file will be presented in XML format for download.
If you experience unexpected behavior of the device you may be asked by
the Junger service team to send such file by e-mail for analysis.
[2 x 2]
Shows the program configuration (2 times 2 channel). This is also
the default configuration of the audio processing blocks.
Each of the two possible programs has a name that will be used
as a reference for the display of parameters and their setup.
You may edit the default names.
shows the status of the 5 tier sync priority circuit
active sync source
measured sample rate
[ON / OFF]
If you enable the checkbox you will get this information:
18
D*AP4