Setup Gui - System - Setup - junger V*AP Manual

Digital voice processor
Table of Contents

Advertisement

Diagnostics
get diagnostics file
Setup GUI – SYSTEM – Setup
V*AP Voice Channel Mode
Section Channel Labels
Voice 1
Voice 2
Program
Sync Source Priority
Choice 1
Choice 2
Choice 3
Choice 4
Fallback (Sync Error)
AES Select
Accept SDI Generator
Pressing this soft button will start the assembly of a diagnostics file.
The file will be presented in XML format for download.
If you experience unexpected behavior of the device you may be asked by
the Junger service team to send such file by e-mail for analysis.
[2 x Mono / Stereo]
Input the type of mic use. This will automatically configure all
relevant audio processing blocks.
Each of the individual voice channels as well as the program path
has a name that will be used as a reference for the display of
parameters and its setup. You may use names of your choice.
[OFF / Internal / Sync-In WCKL / Input AES /
Sync-In Black Burst/Tri Level]
with the Choice x pull downs you may select a sync source for each
state. The choices represent a fall back order from top to bottom.
Internal
Will be selected automatically if none of the above choices are
available.
[Sync-In BNC / Input AES 1/2 XLR]
[On / Off]
If an SDI interface is installed you may use its video test generator
to provide the sync for the device.