General Sets; Pumps Sets - Fimap MXR Workshop Manual

Hide thumbs Also See for MXR:
Table of Contents

Advertisement

General Sets

MENU
DEFAULT
General Sets:
Language: ##
General Sets:
Mod: ###
General Sets:
Battery: ##
General Sets:
Rst.Cnthr: ##
General Sets:
Rst.Main Cnthr: ##
Brushes Sets
Parameter
Default
Brushes Sets:
50
I Max: ## [Amp]
Brushes Sets:
22
I Nom: ## [Amp]
Brushes Sets:
30
T Nom: ## [s]
Brushes Sets:
0.2
T Off: #.# [s]
Brushes Sets:
10
T Reset: ## [s]
Brushes Sets:
0.5
T On: #.# [s]
Brushes Sets:
17
Eco Speed: ## [V]
Brushes Sets:
15
Lev.1: ### [A]
Brushes Sets:
25
Lev.2: ### [A]
Brushes Sets:
35
Lev.3: ### [A]

Pumps Sets

Parameter not managed
VALUES
DESCRIPTION
IT
IT-EN-FR-SP-
Setup the language of the display.
DE
Mxr
. . .
Setup of the machine model (Normal version or with dosing
system).
GEL
GEL-WET-
Setup of the battery type.
AGM-GE1-
WE1
N
Reset partial hourmeter (like on "working menu").
N
Reset total hourmeter (key, brush, vacuum, traction).
Min
Max
Description
20
80
Maximum current from the main card to the brush motor.
10
40
Rated current; with T Nom manages the amperometric protection
(alarm + stop brush motor).
1
60
Rated timer; with I Nom manages the amperometric protection
(alarm + stop brush motor).
0.0
10.0
Delay of switching off of the brush motor when the safety lever is
released.
0
100
Timing of reset amperometric protection (overcurrent).
0.0
5.0
Delay to switching on of the brush motor when the safety lever is
pressed.
15
20
Value of Voltage reduction of brush motor, during ECO mode.
5
35
Parameter not managed.
5
35
Parameter not managed.
5
35
Parameter not managed.
5-47

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MXR and is the answer not in the manual?

Table of Contents

Save PDF