I/O Parameters
Read Duration Output
Useful in evaluating actual read cycle timing results, especially when initially setting up
an application to determine maximum line speed (obtainable based on spacing between
symbols.)
When enabled the duration of the read cycle (in milliseconds) is appended to the symbol data.
The read duration is the time from the beginning of the read cycle until data is output.
Important: To measure the entire read cycle when in
When to Output Symbol Data
This output can measure over 49 days' worth of duration; if exceeded, the "OVERFLOW"
message will be output in place of the duration.
Separator
User-defined character that separates the symbol information from the Read Duration
Output.
5-102
External Level
to
End of Read
Cycle.