Analogue Station Initial Data Setup - NEC Xen Topaz Programming Manual

Xen topaz system
Hide thumbs Also See for Xen Topaz:
Table of Contents

Advertisement

Program 40 to 92
IN
SA
SB
Description
Use Program 82-04 : Analogue Station Initial Data Setup to define the various basic timers for the
308M/308ME Card.
Input Data
Prog. No.
Item
82-04-01
Companding method type
82-04-02
Ringing frequency
82-04-03
- Not Used -
82-04-04
- Not Used -
82-04-05
- Not Used -
82-04-06
- Not Used -
82-04-07
Minimum Hook Flash Time
82-04-08
Maximum Hook Flash Time
82-04-09
Minimum Ground Flash Time
82-04-10
Minimum Off-Hook Time
82-04-11
No detection time after Off-Hook
82-04-12
No detection time after pulse dial de-
tection
82-04-13
Loop disconnect time, Reversal time
82-04-14
Ring, Message wait period time
Conditions
None
Feature Cross Reference
None
P
80: B
ROGRAM
ASIC
81-04: A
H
S
ARDWARE
S
NALOGUE
TATION
Input Data
0 : µ-law
1 : A-law
0 : 25Hz
1 : 20Hz
2 : 16Hz
-
-
-
-
1-255(5ms-
1275ms)
1-255(5ms-
1275ms)
1-255(5ms-
1275ms)
1-255(5ms-
1275ms)
1-255(5ms-
1275ms)
1-255(5ms-
1275ms)
1-255(5ms-
1275ms)
1-255(5ms-
1275ms)
Xen Topaz Programming Manual
E
ETUP FOR
XTENSION
I
D
S
NITIAL
ATA
ETUP
Related
Default
Program
1 (A-law)
0 (25Hz)
-
-
-
-
17 (85ms)
28 (140ms)
21 (105ms)
21 (105ms)
60 (300ms)
70 (350ms)
60 (300ms)
150
(750ms)
305

Hide quick links: