Program 81 : Basic Hardware Setup for Trunk

Level
IN
Description
Use Program 81-01 : CO Initial Data Setup to define the various basic data parameters for the COIU.
Program
81
Input Data
Item No.
01
02
03
04
05
06
07
08
09
10
11
14
15
16
17
20
21
22
23
27
2-426
Item
PCM Encoding Method Specifica-
tion
Loop Current Detection Time
Clear Signal (Open Loop) Detec-
tion Time
Ringing Signal Detection Mini-
mum Time
Single Ringing Detection Mini-
mum Time
Double Ringing Detection Mini-
mum Off Time
Double Ringing Detection Maxi-
mum Off Time
Ringing Signal not Detection
Minimum
Time Ringing Signal Stop Detec-
tion Time
Continuous Ringing Minimum
Time
Continuous Ringing Maximum
Time
Hook Flash 1 Time
Hook Flash 2 Time
Pause Time
PFT Idle Detection Time
Loop Reverse Detect Minimum
Time
Loop Reverse Detect Maximum
Time
Loop Disconnect Detect Mini-
mum Time
Loop Disconnect Detect Maxi-
mum Time
Dial Pulse Break Time (10pps)

81-01 : CO Initial Data Setup

Input Data
0 = μ-law
1 = A-law
1 ~ 255
60 (600 ms)
(10 ~ 2550 ms)
1 ~ 255
59 (295 ms)
(5 ~ 1275 ms)
1 ~ 255
10 (100 ms)
(10 ~ 2550 ms)
0 ~ 255
66 (660 ms)
(0, 10 ~ 2550 ms)
0 ~ 255
10 (100 ms)
(0, 10 ~ 2550 ms)
0 ~ 255
40 (400 ms)
(0, 10 ~ 2550 ms)
1 ~ 255
70 (700 ms)
(10 ~ 2550 ms)
1 ~ 255
50 (5000 ms)
(100 ~ 25500 ms)
0 ~ 255
30 (300 ms)
(0, 10 ~ 2550 ms)
0 ~ 255
70 (700 ms)
(0, 10 ~ 2550 ms)
1 ~ 255
80 (800 ms)
(10 ~ 2550 ms)
1 ~ 255
25 (2500 ms)
(100 ~ 25500 ms)
1 ~ 255
30 (3000 ms)
(100 ~ 25500 ms)
1 ~ 255
30 (3000 ms)
(100 ~ 25500 ms)
1 ~ 255
10 (100 ms)
(10 ~ 2550 ms)
1 ~ 255
86 (860 ms)
(10 ~ 2550 ms)
1 ~ 255
50 (500 ms)
(10 ~ 2550 ms)
1 ~ 255
70 (700 ms)
(10 ~ 2550 ms)
1 ~ 255
13 (65 ms)
(5 ~ 1275 ms)