Use Program 20-15 : Ring Cycle Setup to define the ringing cycles for each ring type.
Input Data
Prog.
Incoming Ring Type
No.
20-15-01
Normal Incoming Call on Trunk
20-15-02
PBX,CES incoming Call
20-15-03
Internal Incoming Call
20-15-04
DID/DISA
20-15-05
DID
20-15-06
-Not Used-
20-15-07
Doorphone ringing for SLT
20-15-08
Virtual Extension Ring
20-15-09
Call-back
20-15-10
Alarm for SLT
20-15-11
VRS Waiting Message Incoming
Call
Ring Cycle
Ring Cycle No.
1
Not Supported
2
On:2.0 / Off:4.0
3
On:1.0 / Off:2.0
4
On:0.5 / Off:0.5
5
On:0.3 / Off:0.3
6
On:0.5 / Off:0.5 / On:0.5 / Off:1.5
7
On:0.4 / Off:0.2 / On:0.4 / Off:2
8
On:0.3 / Off:0.3 / On:0.3 / Off:2.1
9
On:0.2 / Off:0.2 / On:0.2 / Off:0.2 / On:0.2 / Off:2.0
10
On:1.0 / Off:4.0
11
On:0.3 / Off:0.3 / On:0.3 / Off:4.1
12
On:1.0 / Off:3.0
13
On:0.3 / Off:0.3 / On:0.3 / Off:2.1
Conditions
None
Xen Topaz Programming Manual
P
ROGRAM
Ring Cycle No.
1-13
Ring Cycle
138
Program 16 to 20
20: S
O
YSTEM
PTION
20-15: R
C
ING
YCLE
Default
3
8
8
8
8
8
2
8
4
5
6
S