● Changing the search area
Change the area to search edges or the model.
Specify the top left coordinate and bottom left coordinate of the area.
2004/09/24
MENU mode-[CUSTM]-[MODE DTL]-[SEARCH AREA]
When searching edges
Measurement can be performed only when the search area contains an edge. Determine the size
and position of the area taking the movement range of the workpiece into consideration.
● Raising detection stability
This item is displayed only when [CHARA2] is set.
MENU mode-[CUSTM]-[STABLE]
Setting
OFF (default)
ON
Detecting Presence of Character String (CHARA)
Search area
2004/09/24
Standard detection method.
Detailed detection method.
The process time is longer than OFF.
Section 4
Search area