Section 5
Setting for Amplifier Unit Gang-Mount

Restrictions when Gang-Mounting Amplifier Units

■ ZFV-A_ _ Gang-mounting units
The ZFV-A_ _ units cannot be gang-mounted.
■ ZFV-CA Gang-mounting multiple units
To use two or more ZFV-CA units by gang-mounting them to each other, the following
hardware and software are required:
Hardware: Amplifier unit with serial number;
Software: Firmware version 1.30 or later
■ ZS-DSU Gang-mounting
To gang-mount the ZS-DSU and ZFV-CA units, the following software is required:
ZS-DSU: Firmware version 2.220 or later
ZFV-CA: Firmware version 1.30 or later
A maximum of five ZFV-CA units can be gang-mounted to a ZS-DSU unit.
Note, however, that any other unit (ZS-HLDC/LDC/MDC, ZFV-A) cannot be connected between the
ZFV-CA and ZS-DSU units.

Saving the Settings Conditions

The set measurement conditions are saved on the Amplifier Units automatically when the
mode is switched to RUN. Please be aware that no confirmation message will appear at
this time.
If the power is turned OFF before the conditions are saved, any changes made will be lost
including the results of teaching operations.
Measurement conditions save automatically in RUN mode if a TEACH signal is input from external
and teaching is successful. Changes to the measurement conditions will not be saved automatically
when teaching is executed using the TEACH key on the Teaching menu screen unless the mode is
switched to RUN at least temporarily.
ZFV-C
118
User's Manual
ZFV-CA40: 0218206 or bigger
ZFV-CA45: 0003206 or bigger